Expansion Slots

Expansion Slots

Expansion Slots

Expansion Slots

Expansion

Expansion

Expansion

Expansion

Slot #

Slot #

Slot #

Slot #

Technology

Technology

Technology

Technology

Width

Width

Width

Width

Connector

Connector

Connector

Connector

Width

Width

Width

Width

*

Bus

Bus

Bus

Bus

Number

Number

Number

Number

**

Form Factor

Form Factor

Form Factor

Form Factor

Notes

Notes

Notes

Notes

1

PCI-X

64-bit

N/A

42h

FH/HL

100MHz

2

PCI-X

64-bit

N/A

42h

FH/FL

100MHz

3

PCI Express

x4

x8

49h

FH/FL

4

PCI Express

x4

x8

4Ch

FH/FL

5

PCI Express

x8

x16

46h

FH/FL

6

PCI Express

x4

x8

4Fh

FH/FL

7

PCI Express

x8

x16

02h

FH/FL

8

PCI Express

x8

x16

05h

FH/FL

9

PCI Express

x4

x8

08h

FH/HL

Reserved for

storage

controller

* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID
by bus (starting with the lowest bus).
FH = Full height; FL = Full length; HL = half-length; LP = Low profile.

Manageability

Manageability

Manageability

Manageability

Integrated Lights-Out 2 (iLO 2) Standard Management (ASIC on the System Board)

Storage Controllers

Storage Controllers

Storage Controllers

Storage Controllers

One of the following
depending on Model

HP Smart Array P400/256MB Controller (in a PCI-Express slot)

NOTE:

NOTE:

NOTE:

NOTE: Standard on 2.0GHz and 2.2GHz models.

HP Smart Array P400/512MB BBWC Controller (in a PCI-Express slot)

NOTE:

NOTE:

NOTE:

NOTE: Standard on 2.4GHz, 2.6GHz, 2.8GHz, and 3.0GHz models.

Storage Data Protection

Storage Data Protection

Storage Data Protection

Storage Data Protection

The Battery-Backed Write Cache (BBWC) Enabler for the Smart Array P400 Controller protects up to
512-MB write cache memory from hard boot, power, controller, or system board failures.

Standard on all HP ProLiant DL585 G2 Models
Battery charge/life: Up to 72 hours/3 years
Transportable data protection
Increases overall controller performance

NOTE:

NOTE:

NOTE:

NOTE: Safely transport your write cache data to another HP ProLiant DL585 G2 in the data center by
removing the BBWC Enabler and Smart Array P400 Controller Memory Module simultaneously
(connected by short cable).