TruTrak Altrak VS User Manual

Page 8

Advertising
background image

TruTrak Flight System

6

Altrak Installation & User Guide

January 2009

8300-014 Rev B

Electrical Pin-Out


The table below provides a brief explanation of each pin function on the main 15-pin connector P101.

P101
Pin

Function

Notes

1 Autopilot Master (+12 to +14 V DC). The autopilot itself draws less than 0.3 ampere.

Most of the current required by the system is used by the servo (up to 1Amp depending
on torque setting).

See note 3 on wiring
diagram

2 Control Wheel Switch. Connect as shown in wiring di

agram to a SPST momentary

switch

located remotely to the autopilot for convenient disengage function.

See note 3 on wiring
diagram

3 On / Off Switch. Connects to the illuminated push button module

4 Pitch Reverse Jumper,

present or absent, as follows:

Direction of the servo arm / capstan rotation
( as viewed from face of the servo body) for
UP

elevator

See note 2 on wiring
diagram

Pin 4 open ( no connection)

Servo CCW (counter-clockwise) UP

Pin 4 Jumpered to pin 15

Servo CW (clockwise) → UP

5 Pitch Servo Trim Sensor. A signal from the pitch servo to the autopilot which indicates

an out-of-trim condition and its direction. (For use with trim sensing servo upgrade)

6 Engage Lamp / LED Connects to LED which connects to 470 ohm resistor.

See Module Rear View
on wiring diagram

7 Pitch Servo Torque Control. A signal from the autopilot to the pitch servo which sets

the amount of torque to be delivered by the servo.

8 VS control input from button assembly on panel.

VS Option only

9 AP On. Connect to pin 7 on Digitrak / Pictorial Pilot/Pictorial Pilot (This function is

only to be used if Altrak is coupled to Digitrak / Pictorial Pilot/Pictorial Pilot.)

See note 3 on wiring
diagram

10 Activity Select. Connect to ground for low activity, leave open for medium activity, and

connect to 12v for high activity

See note 4 on wiring
diagram

11
12
13
14

Pitch Servo control lines

. These lines cause the stepping motor in the pitch servo to run

in the appropriate direction at the desired velocity. They are small-signal lines and do not
have any substantial current-carrying capability or require any special shielding. Connect
to pitch servo as shown on wiring diagram.

Do NOT attempt to
reverse servo direction
by swapping wires

15 Ground Connection. Provide #20 AWG to common grounding point.