Panel mount gps – TruTrak Pictorial Pilot User Manual

Page 10

Advertising
background image

Panel mount GPS

Garmin 155XL/250XL/300XL

Garmin 155XL/250XL/300XL connections to TruTrak autopilot

J1 on

Garmin unit

Signal Name

(Garmin)

Signal Name

(TruTrak)

P101 on

TruTrak PP

19

GPS RS 232 OUT 2

Primary Serial Input

3

Press & hold MSG, rotate outer knob until I/O setup page is displayed. Press CRSR twice and rotate inner knob to select
“plotting” for output to autopilot. Rotate outer knob to advance cursor to the baud rate field, select 9600. Press CRSR to
finish.

Note that for the Garmin units, the autopilot will need to be set for 9600 baud.

Garmin 430 and 530

Garmin 430 and 530 connections to TruTrak autopilot

P4001 [P5001] on

Garmin 430 [530]

Signal Name

(Garmin)

Signal Name

(TruTrak)

P101 on

TruTrak PP

56

GPS RS 232 OUT 1

Primary Serial Input

3

Power 430/530 up and turn it on while holding down the ENT key. Release the ENT key when the display activates. After the
data base pages, the first page displayed is the MAIN ARINC 429 CONFIG page. While in Configuration mode, pages can be
selected by ensuring the cursor is off and rotating the small right knob. To change data on the displayed Configuration Page,
press the small right knob (CRSR) to turn on the cursor. Turn the large right knob to change between data fields. Turn the large
or small right knob to change a field that the cursor is on. Once you have made the desired selection, press the ENT key to
accept the entry.

Advance to the MAIN RS232 CONFIG page.

On the row labeled CHNL1, select OUTPUT Î Aviation.

Note that for the Garmin units, the autopilot will need to be set for 9600 baud.

UPSAT GX-50/60/65

UPSAT GX-50/60/65 connections to TruTrak autopilot

37-Pin Connector

on UPSAT

GX-50/60/65

Signal Name

(UPSAT)

Signal Name

(TruTrak)

P101 on

TruTrak PP

5

Use pin 5 – TxD1

Primary Serial Input

3

Power the GX-50/60/65 up and turn it on while holding down the leftmost and rightmost “smart keys.” Rotate the LARGE
knob to the Serial Interface Configuration “CH RX TX” page. Press SEL (the selection fields will start flashing), rotate the
LARGE knob to select the port, rotate the SMALL knob to select the desired configurations, and then press ENT when
complete.

If both the GX unit AND the DigiFlight unit have GPSS capability,

select “GPSS” for CH 2, TX column, and wire pin 17 on the DigiFlight IIVSG to pin 22 of the GX unit

Otherwise

select “MOVING MAP” For CH 1, TX column and wire pin 17 on the DigiFlight II / IIVS to pin 5 of the GX unit

To restore the GX-50/60/65 to normal operation, switch its power off, and then back on.

Note that for the GX-50/60/65 units, the autopilot will need to be set for 9600 baud.
TruTrak Flight Systems Pictorial Pilot Installation & User Guide
December 2009 8 8300-011 Rev B

Advertising