Appendix b – axial fans – Twin City Fans With CE Mark - ES-2-06 User Manual

Page 14

Advertising
background image

14.

Twin.City.Fan.Engineering.Supplement.2-06

Axial Fans - Securing the Wheel to the Shaft

If.the.propeller.is.removed.for.any.reason,.make.sure.that.

it.is.securely.attached.to.the.shaft.before.restarting.the.

fan..If.the.propeller.is.attached.to.the.shaft.by.means.of.

a. Trantorque. bushing,. use. the. tightening. torque. values.

shown.in.Table.6.below..For.other.bushings,.see.table.3.

for.proper.torque.values.

Axial Fans with Adjustable Blade Angles

The.blades.are.set.at.the.factory.to.the.blade.angle.that.

gives.the.performance.specified.on.the.order..This.angle.

should. be. checked. prior. to. start-up.. The. blade. angle.

should. not. be. changed. from. that. stated. for. the. order.

without. assuring. that. a. change. in. blade. angle. will. not.

overload.the.motor,.any.controls,.or.other.items..Vibration.

levels. shall. also. be. checked. in. accordance. with. ISO.

14694:2003,.“Industrial.Fans.–.Specifications.for.Balance.

Quality.and.Vibration.Levels”.if.any.change.is.made.to.

blade.angles.

Appendix B – Axial Fans

Blade Adjustment on Adjustable Pitch Vaneaxial
Type TCVX, VJ

The. patented. wheel. construction. uses. friction. and. cen-

trifugal.force.to.hold.the.blades.in.place..No.disassembly.

of.the.wheel.is.required.to.change.the.blade.angles..If.

it.is.necessary.to.change.the.blade.angle,.the.following.

procedure.should.be.used:

1..Work.safely..Make.sure.that.proper.safety.precautions.

have.been.followed..Electrical.power.must.be.locked.

off.

2..The.adjustment.can.be.made.through.the.inlet.on.open.

inlet.fans..On.fans.with.ducted.inlets,.open.the.wheel.

area.access.door.

3..Place.adjustment.tool.around.end.of.blade.(see.Figure.

10)..If.necessary,.apply.“cheater.bar”.around.the.11/4".

(31.75mm). diameter. end. for. additional. leverage.. The.

blades.can.be.turned.by.hand.on.open.inlet.fans..If.

additional.leverage.is.needed,.place.a.wrench.on.the.

leading.edge.of.the.blade.near.the.hub..Take.care.not.

to.mar.the.surface.of.the.blade.

Blade Adjustment on Type "E" Adjustable Pitch
Propeller

Preferred Method (more Accurate)

1..Lay.the.hub.on.a.horizontal.surface.with.the.concave.

(air.leaving).surfaces.of.the.blades.facing.upwards.

2..Loosen.the.blade.retaining.bolts.until.they.are.finger-

tight.. At. this. point,. the. blades. should. rotate. in. their.

sockets.when.grasped.firmly.and.twisted,.but.not.turn.

on.their.own.

3..Place.an.angle.meter.across.the.two.blade.angle.posi-

tion.marks.on.a.blade..See.Figure.11.

4..Twist.the.blade.to.the.desired.blade.angle.
5..Repeat.steps.3.and.4.for.the.remaining.blades.

Trantorque

Size

Shaft

Diameter

Socket

Size

Torque

Ft-Lb

N-m

7/8

7/8

1-1/2

71

96

1-1/8

1-1/8

1-3/4

130

176

1-3/8

1-3/8

2

141

191

1-5/8

1-5/8

2-1/4

233

316

1-7/8

1-7/8

2-1/2

325

441

2-1/8

2-1/8

2-3/4

440

597

2-3/8

2-3/8

3

470

637

2-7/8

2-7/8

3-1/2

550

746

Table 6. Trantorque Bushing Torque Values

Note:.These.torque.values.are.to.be.obtained.with.a.calibrated.
torque.wrench..DO.NOT.apply.any.lubricant.to.any.part.of.the.
Trantorque

®

. hub.. DO. NOT. use. an. anaerobic. thread. adhesive.

such.as.Loctite

®

.on.the.threads.

Figure 9. Typical Hooded Roof Ventilator Installations

HINGED.HOOD

BOLTED.HOOD

SIZE.12".–.42".ACCESS
DOOR.FOR.INSPECTION

SIZE.48".–.60"

ACCESS.DOOR.FOR.DAMPER.
REMOVAL

SAFETY.SCREEN.STANDARD.
OPTIONAL.DAMPER.NOT.SHOWN.

OPTIONAL.DAMPER

Appendix A – Commercial Ventilator Installation instructions

(cont'd)

Hooded Ventilators

Hooded. units. sizes. 12. to. 42. use. a. one-piece. hinged.

hood.. To. lift. the. hood,. remove. the. two. bolts. located.

under.the.mushroom.cap.and.prop.the.hood.up.with.the.

supplied.safety.rods..Push.and.lock.into.place..A.screw.

is.installed.at.the.end.of.the.pin.side.of.the.hinge.in.the.

hood.angle.to.prevent.accidental.removal.of.the.hood..To.

close.the.hood,.replace.the.bolts.to.lock.in.place..For.

size.48,.a.one-piece.bolted.hood.connects.directly.to.the.

fan.stack..To.lift.the.hood.off.the.unit,.remove.the.bolts.

located.under.the.mushroom.cap..For.sizes.54–72,.a.two-

piece.bolted.hood.connects.directly.to.the.fan.stack..To.

lift.the.hood.off.the.unit,.remove.the.sheet.metal.bolts.

than. connect. the. right. and. left. sides. of. the. hood. and.

then.remove.the.bolts.located.under.the.mushroom.cap..

See.Figure.9.below.

Advertising