Use and care, Mounting options, Electrical connections – Twin City Inline / Cabinet Ventilators - TL Series User Manual

Page 15: Accessory installations, Accessories, Page 3

Advertising
background image

Page 3

MODELS • T2000L • T3500L

WARNING: To reduce the risk of electric shock,

disconnect from power supply before servicing.

To clean grille: Use appropriate vacuum attachment or remove

grille and clean with a soft cloth and mild soap or detergent. Dry

grille thoroughly before reinstalling.
To clean blower assembly: Remove either access panel or ceil-

ing grille. Unplug blower assembly. Provide safe support for blower

assembly. Remove blower mounting screws and lift blower assem-

bly out of housing. Gently vacuum housing and blower motor.

Vacuum or gently wash blower wheels and housings. DO NOT AL-

LOW WATER TO ENTER MOTOR. Make sure blower assembly is

completely dry before reinstalling. Replace blower assembly in hous-

ing and plug assembly in. Replace grille and/or access panel.
Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may

be controlled using an on/off switch or a solid-state, variable speed

control. Follow wiring instructions packed with control, and adhere

to all local and state codes, and the National Electrical Code.

MOUNTING OPTIONS

EXHAUST

ACCESS

PANEL

INTAKE

SLEEPER

1-1/4”

Connect electrical power cable to housing with proper connector

for type of cable used. Provide 6” leads inside wiring box.

ELECTRICAL CONNECTIONS

MOTOR

MOTOR

MOTOR

MODEL

T3500L

MODEL

T2000L

SPEED CONTROL

OR SWITCH

SPEED CONTROL

OR SWITCH

LINE IN

120 VAC

60 HZ

LINE IN

240 VAC

60 HZ

1 PHASE

WHITE

GND

BLK

RED

GND

BLK

ACCESSORY INSTALLATIONS

NOTE: If duct flanges around intake opening interfere with installa-

tion, remove them. Make sure that housing is flush with finished

ceiling when ventilator is mounted.

OUTSIDE

DAMPER BUSHING

(Snaps over rod)

INSIDE DAMPER

BUSHING

(Inside of frame)

DAMPER FLAP

(Should open freely)

CABINET FLUSH

CEILING

GRILLE

NUTS

GRILLE

SCREWS

If ventilator will discharge directly outside, install adamper kit to

prevent backdrafts. A grille kit is available for applications where

ventilator is installed with direct or remote room air intake.

ROD

(Inserts into inside bushing)

DUCT FLANGES

DAMPER

GRILLE

SPEED

VIBRATION

MODEL

KIT

KIT

CONTROL HANGER

T2000L

D100

G102

72V / 72W

V104

T3500L

D101

G103

75V

V104

ACCESSORIES

Typical wall mounting with 3/8” threaded fasteners

(by others) through mounting brackets.

Snap screw bushings into square openings around intake

opening. Install grille with screws provided.

Install damper flap using rod provided.

Advertising