CCE-100

INSTRUCTION MANUAL

Ultra Stereo Labs, Inc.

- 12 -

CCE-100

INSTRUCTION MANUAL

Ultra Stereo Labs, Inc.

- 13 -

Streaming Log

The CCE-100 makes a streaming log available on TCP port 10001. You may

view this log using telnet, a terminal program such as Tera Term, or by using the
PCMan Firefox extension. If the IP address of the CCE-100 is 192.168.1.158, a
telnet command to view the streaming log would be “telnet 192.168.1.158 10001”.
With the PCMan Firefox extension, it’s possible to just click the “Telnet to port
10001 on this device to see a streaming log.” link on the CCE-100 home page to
view the log. A typical streaming log screen from within Firefox is below.

Basic DCS Test

You can verify whether the DCS supports SMPTE captioning by using a laptop

to connect to the Content Synchronization Port. Disconnect the CCE-100 from
the network. Set your laptop to the IP address of the CCE-100. Use Tera Term
or telnet to connect to the DCS on port 4170. For example, the command “tel-
net 192.168.1.189 4170” (assuming the DCS IP address is 192.168.1.189) should
connect, dump some garbage that normally includes the model of the DCS. If the
laptop cannot connect to the DCS on port 4170, there may be networking, DCS
configuration, or DCS software issues.

At times, it can be difficult to determine the IP address of the CCE-100. You can

use the Ethernet Discoverer at http://www.uslinc.com/products-sound-CCE100.
html to determine the IP address of the CCE-100. Clicking on the text line for the
caption encoder in the Ethernet Discoverer window will open a web browser point-
ing to that IP address. If the IP address is on the same subnet as your computer,
you should see the opening page of the caption encoder.

Finding The Box

TROUBLESHOOTING

System Status Page

A System Status page is available from the selections at the top of the configu-

ration page. This page shows the last 10 log entries. However, the streaming log,
described below, is more useful.

An Update Firmware page is available from the selections at the top of the

configuration page. Use this page to load new firmware into the CCE-100. During
the update, the front panel LEDs on the CCE-100 will flash. When the update is
complete, a blank page will appear on the browser. Enter the IP address of the
CCE-100 in the browser URL field to reconnect to the CCE-100 and verify that the
version number has changed to the new version. All user configuration is saved
through a firmware update.

Update Firmware Page