Locating stove continued, Minimum clearances to combustible surfaces – Vogelzang BX22EL User Manual
Page 7
VGZ-003 / 20120224.1
BX22EL /
Page 7
Figure 9 – Top View
Minimum Corner Clearances from
Combustible Surfaces
30"/76.2cm
CORNER CLEARANCES
30"/76.2cm
LOCATING STOVE continued…
COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211
FLOOR
PROTECTOR
DASHED LINE SHOWS
HORIZONTAL CHIMNEY
CONNECTOR AND
ADDITIONAL FLOOR
PROTECTION REQUIRED
BACKWALL
27"/68.6cm
(TOP VIEW)
8"/21cm
8"/21cm
8"/21cm
32"/81.3cm
36"/91.4cm
51"/129.6cm
18"/46cm
SIDEWALL
COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211
34.5"/87.6cm
Figure 7 – Minimum Clearance Dimensions
from Combustible Surfaces
Figure 8 – Top View Minimum Clearance
Dimensions from Combustible Surfaces
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.
MINIMUM CLEARANCES
TO COMBUSTIBLE SURFACES
Unit to Sidewall ...............................................36˝ / 91.4cm
Unit to Backwall ..............................................32˝ / 81.3cm
Unit Corner to Wall ..........................................30˝ / 76.2cm
Pipe Connector to Backwall ........................34.5˝ / 87.6cm
Pipe Connector to Ceiling ...............................18˝ / 45.7cm
9. This stove meets Test Standards: UL 1482-2011
and Canadian Standard: ULC-S627-00.
Failure to follow these minimum clearance re-
quirements may result in an unsafe installation
and could cause a fire.
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.
WARNING: DO NOT USE SINGLE WALL CON-
NECTOR PIPE AS A CHIMNEY - A HOUSE FIRE
COULD RESULT.