Locating stove continued – Vogelzang TR008 User Manual
Page 7

TR008-96 | 20120425.0
www.vogelzang.com
DURANGO™
| Page 7
FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
AND EXTENDING 2” BEYOND EACH SIDE
COMBUSTIBLE CONSTRUCTION PER NFPA 211
BACKWALL
SIDEWALL
31"
4 8"
16"min.
6"min.
17"
22"
min.
25.8"
min.
14"
min.
11"
min.
TOP VIEW
29"
TR008
CAUTION: FAILURE TO FOLLOw ThESE
M I N I M U M C L E A R A N C E R E q U I R E -
MENTS MAY RESULT IN AN UNSAFE
INSTALLATION AND COULD CAUSE A FIRE.
8. T h i s s t ove m e e t s U. S. Te s t S t a n d a r d :
UL 1482-1996.
9. Always locate stove to provide a source of fresh
air into the room where the unit is installed.
Failure to do so may result in air starvation of other
fuel burning appliances and the possible develop-
ment of hazardous conditions.
NOTE: ANY wALL CONTAININg COMBUSTI-
BLE MATERIAL SUCh AS wOODEN STUDS OR
DRYwALL AND FACED wITh BRICk OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
6. DO NOT INSTALL ThIS STOVE IN A MOBILE
hOME, MANUFACTURED hOME, TRAILER OR
TENT – NO EXCEPTIONS! (HUD FEDERAl
STANDARD: 24 CFR CH.xx)
7. T h e c l e a ra n c e s p r ov i d e d a r e m i n i mu m
dimensions determined by OMNI-Test Lab-
oratories, Inc., the manufacturer’s testing
laboratory. Installation of this stove must
comply with the latest edition of NFPA 211 for
reduced clearances and/or your local build-
ing code rulings. Use whichever minimum
dimensions are LARGEST.
Fig. 5 – Top View minimum Clearance Dimensions from
Combustible Surfaces
13"
19"
19"
13"
CORNER CLEARANCES
Fig. 6 – minimum Corner Clearance
Dimension from Combustible Surfaces
Fig. 7 – Front & Side Views: Minimum Clearance Dimensions
from Combustible Surfaces
CAUTION: kEEP FURNIShINgS AND
OThER COMBUSTIBLE MATERIALS
AwAY FORM ThE STOVE AND OUTSIDE
MINIMUM CLEARANCES.
lOCATING STOVE continued…