Safety information, Warning, Ccaution warning – Water Factory Systems CMTRO-75 User Manual

Page 2: Caution, Explanation of signal word consequences

Advertising
background image

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

CAUTION

IMPORTANT NOTES

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CMTRO-75™
Reverse Osmosis (RO) Drinking Water System. Retain these instructions for future reference.

Intended use:
The CMTRO-75 Reverse Osmosis (RO) Drinking Water System is intended for use in fi ltering potable water in the home or offi ce and has not
been evaluated for other uses. The system is typically installed in a cooler, under a sink or in a basement, and must be installed as speci-
fi ed in the installation instructions.

C

CAUTION

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury
and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury
and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

To reduce the risk associated with choking:

Do not allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certi-

fi ed for cyst reduction may be used on disinfected water that may contain fi lterable cysts. EPA Establishment Number 070595-CT-001

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of
installation:

Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the fi lter bracket.

To reduce the risk of physical injury:
• Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.

• All hydropneumatic pressurized tanks must have an appropriate pressure relief valve installed.

To reduce the risk with back strain:
• Follow safe lifting procedures.

To reduce the risk associated with eye, skin and respiratory and digestive tract burns from Calcium Hypochlorite during installation:
• Calcium Hypochlorite (CAS 7778-54-3) granules are used for tank sanitization in this product.
• During installation, do not get in eyes or on skin or clothing. Do not ingest. Wear eye and face protection. Keep out of reach of children.
• To request an MSDS relating to this product, call 203-238-8965 or visit the web at http://solutions.3m.com/wps/portal/3m/en_us/MSDS (click

MSDS search). For emergencies, call 800-364-3577 or 651-737-6501 (24 hours).

To reduce the risk associated with ingestion of water contaminated with sanitizer:
• After installation, sanitizer MUST be fl ushed from the system before fi rst use as directed within the installation instructions.

To reduce the risk of injury associated with household bleach:
• Read and follow manufacturers directions and cautions. Keep out of reach of children.
DO NOT intermix with other chemicals.

To reduce the risk associated with property damage due to water leakage:
Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
Do not install on hot water supply lines. The maximum operating water temperature of this fi lter system is 100°F (37.8°C).
Do not install if water pressure excee

ds 100 psi (689 kPa).

If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting

valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact

a plumbing professional if you are uncertain how to check for this condition.

Do not use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.
• Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to themal expansion must be installed.
• All hydropneumatic pressurized tanks must have an appropriate pressure relief valve installed.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only. Pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if overtightening occurs.
Do not install in direct sunlight or outdoors.
Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount

fi lter in such a position as to prevent it from being struck by other items used in the area of installation.

• Ensure that the location and fasteners will support the weight of the system when installed and full of water.
Do not install unit if collet is missing. Contact CUNO Tech Services (203-238-8847) if collets are missing from any fi ttings.
• Ensure all tubing and fi ttings are secure and free of leaks.
• The disposable fi lter cartridge MUST be replaced every 18 months, at the rated capacity or if a noticeable reduction in fl ow rate occurs.

• Failure to follow instructions will void warranty.
• Allow a minimum of 2” (5.1 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.

CAUTION

Advertising