Wilkerson F33 User Manual

Installation and maintenance sheet

Advertising
background image

INSTALLATION

1.Refer to the above warning.
2.Install as close as possible to point where air is being used.
3.Install a unit with the same pipe size as the one in use. Avoid using fittings,

couplings, etc. that restrict the airflow.

4.Mount unit in a vertical position.
5.Maximum inlet pressure and operating temperature ratings are trans-

parent plastic bowls, 150 psig (10,3 bar) and 125°F (52°C); metal bowls, 200 psig (14
bar) and 175°F (79,4°C).

MAINTENANCE

1.FILTER ELEMENT - Replace or clean periodically by removing filter, tapping

on hard surface and blowing off with an air gun. When cleaning or replacing
element, blow off louvers with air blow gun.

2.The unit is equipped with a manual petcock; drain the bowl at least once per

work shift.

3.Before placing the unit back in service, make sure the bowl and bowl guard

are reinstalled and clamp ring is securely locked in place.

BAFFLE

NNR

O-RING

TYPE “A”
ELEMENT

PETCOCK
(for metal
bowls only)

PRESS

TURN

RETAINING

SCREW

O-RING

TRANSPARENT

BOWL

BOWL GUARD

NNR

PLASTIC PETCOCK

CLAMP RING

NNR

LOCKNUT

TYPE “A”
ELEMENT

SHIELD

NNR

COVER
NNR

METAL
BOWL

REPAIR KITS AND REPLACEMENT PARTS

Repair Kit (Type A Element) .......................................................FRP-95-170
Bowl O-Ring Kit..........................................................................GRP-95-256
Clamp Ring Assembly................................................................GRP-96-404
Bowl Assembly Kit - no guard ....................................................GRP-96-181
Plastic Bowl w/manual Drain Seat and Bowl Guard ..................GRP-95-726
Bowl Guard ................................................................................GRP-95-808

NNR=NOT NORMALLY REPLACED

83-280-000 REV REL 8/95

Printed in U.S.A.

WARNING

DO NOT PLACE PLASTIC BOWL UNIT IN SERVICE

WITHOUT METAL BOWL GUARD INSTALLED

Plastic bowl units are sold only with metal bowl guards. To minimize the danger of flying fragments in the
event of plastic bowl failure, the metal bowl guards should not be removed. If the unit is in service without
the metal bowl guard installed, manufacturer's warranties are void, and the manufacturer assumes no
responsibility for any resulting loss.
IF UNIT HAS BEEN IN SERVICE AND DOES NOT HAVE A METAL BOWL GUARD, ORDER ONE AND
INSTALL BEFORE PLACING BACK IN SERVICE.
.

For information for materials harmful to plastic bowls, contact a Mobay Chemical or General Electric office for
information regarding materials that will attack polycarbonate plastic.

CAUTION

Certain compressor oils, chemicals, household cleaners, solvents, paints and fumes will attack plastic
bowls and can cause bowl failure. Do not use near these materials. When bowl becomes dirty replace
bowl or wipe only with clean, dry cloth. Reinstall metal bowl guard or buy and install a metal bowl guard.
Immediately replace any crazed, cracked, damaged or deteriorated plastic bowl with a metal bowl or a new
plastic bowl and metal bowl guard.

EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for com-
pressed air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use
with or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum
gas) could be harmful to the unit or result in a combustible condition or hazardous external leakage.
Manufacturer's warranties are void in the event of misapplication, and manufacturer assumes no
responsibility for any resulting loss. Before using with fluids other than air, or for non-industrial applica-
tions, consult manufacturer for written approval.

INSTALLATION AND

MAINTENANCE SHEET

Filter Muffler Model F33

with Variations and Accessories

®

OPERATIONS

Advertising