User manual, English – XMART Supra 2100 User Manual

Page 3

Advertising
background image

USER MANUAL -

SUPRA 1100/1600/2100

ENGLISH

________________________________________________________

www.xmart-ups.com 1303-SUPRA 1100/1600/2100-ENG - 6

7. CONTROL SOFTWARE


Most of the models of this UPS family come with USB port to communicate with your PC. In that way UPS can
be monitored and configured. Your PC can be shutdown automatically when a input AC failure is detected
saving your information and providing a controlled shutdown. Event log and alarms can also be monitored from
your PC.

Control software can be downloaded from our website: www.xmart-ups.com. We keep updated last updated
version. User manual and installation manual is also available in our web.
Our software is available in different versions for: Windows, Mac OSX, Linux and Unix.

8. TROUBLE SHOOTING TABLE

#

PROBLEM

CAUSE

SOLUTION

1

UPS does not turn ON
LED OFF

ON button has not been properly

activated.

Push ON button during 2-3 seconds

Very low battery level

Keep UPS plugged to main service to
recharge batteries

Battery failure

Contact service center to replace
batteries

2

UPS goes to battery mode

even main source is OK
Front LED flashing in green
color.
Intermitent BEEP alarm
activated

Input cable or plug is not
connected to main source

Check and plug properly

Input breaker is activated (open)

Check and reset input breaker

3

Input breaker is activated
frequently

Equipments connected to UPS
outlets overload UPS.

Check and unplug equipment until
overload condition is solved

4


Continuous BEEP alarm.

UPS is overloaded

Check and unplug equipment until
overload condition is solved

5

UPS power off when AC
main source fails
(runtime = 0s)

Low battery level because recent
discharge

Keep UPS plugged to main service to
recharge batteries

Battery failure

Contact service center to replace
batteries



USER MANUAL -

SUPRA 1100/1600/2100

ENGLISH

________________________________________________________

www.xmart-ups.com 1303-SUPRA 1100/1600/2100-ENG - 3

2. QUALITY / PERFORMANCE / SAFETY

SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC)

UPS Part 1-1: General & Safety UPS in accessible areas

IEC/EN 62040-1

ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE ( 2004/108/EC)

UPS, Part 2, Electromagnetic Compatibility:

IEC/EN 62040-2

Low Freq. Conducted Disturbances & Signals:

IEC/EN 61000-2-2

Electrostatic discharge immunity Test:

IEC/EN 61000-4-2

(Air: Level 3, Contact: Level 2)

Radiated radio Frequency immunity:

IEC/EN 61000-4-3 (Level 3)

Electrical Fast Transient / burst immunity:

IEC/EN 61000-4-4 (Level 3)

Surge immunity:

IEC/EN 61000-4-5

(L-L: Level 2, L-G: Level 3)

UPS Part 3: Methods of operation, specifications and test requirement

IEC/EN 62040-3

IT Equipments. SAFETY. Part 1: General Requirements

IEC/EN 60950-1

IP PROTECTION

IP20 (static)

QUALITY MANAGEMENT:

Manufactured under:

ISO 9001 : 2000

ENVIRONMENTAL MANAGEMENT:

Manufactured under:

ISO 14001 : 2004

Any modification made by user or operator may affect compliance of the safety and performance certifications listed above.

UPS manufacturer is not responsible of any modification made on the product or its accessories after it is manufactured.

This product is designed to operate in domestic and commercial environment. CE standards apply for 230Vac models.

3. BATTERIES MAINTENANCE

Batteries capacity, in general (of all kinds), decreases with time and use.

Our products contain high quality batteries only.

Batteries useful life in our UPS is between 3 and 5 years, considering environment temperature under
25ºC and optimal operational conditions. This time can be dramatically reduced by high temperature and

other adverse operation condition.

Batteries life expectancy may be also affected by other operation conditions such as electrical service
quality as well as number and kind of equipments connected to UPS

Batteries should be periodically tested to check capacity and assure and appropriate back up.

* To enlarge batteries life expectancy it is recommendable to fully discharge UPS once every 3 months
* During long UPS storage recharge batteries according to following table:

STORAGE TEMPERATURE

FREQUENCY

RECHARGING TIME

-25°C a +30°C

Every 4 months

4 h

+30°C a +45°C

Every 2 months

4 h