Hexdump, Errorres, Bytewr – Campbell Hausfeld Serial I/O Interface SDM-SIO4 User Manual

Page 28: Start address] [number of bytes, Address] [byte

Advertising
background image

SDM-SIO4 User Guide

4-

4

WD n WDERR n WDADDR n

WD n is a count of the number of watchdog resets, WDERR is the number of the
last task that crashed and WDADDR is the address at which the crash was found.

NC 0-9

This is the number of SDM commands the datalogger sent to the SDM-SIO4 that
the SDM-SIO4 did not recognise. This counter may be incremented when the
program is first compiled in the datalogger due to the auto speed detection of the
datalogger.

PORT1-4

These four sets of values are the current port settings in the order as below:

•

Baud rate setting

•

Data length setting

•

Stop bit setting

•

Parity bit setting

•

Handshake mode

•

Delay time value

•

Parity error count

•

Framing error count

•

Overrun error count

•

Line break error count

•

DTR handshake line status, 0=low 1=high

•

RTS handshake line status, 0=low 1=high

•

CTS handshake line status, 0=low 1=high

•

DSR handshake line status, 0=low 1=high

•

DCD handshake line status, 0=low 1=high

You should refer to the appropriate section of this manual for further specific
detail.

hexdump

[start address] [number of bytes]

This is used by Campbell Scientific for test purposes and outputs a hex dump of
the SDM-SIO4’s internal address space. The start address and number of bytes to
dump must be in base 10, decimal integer.

errorres

This resets all error counters.

bytewr

[address] [byte]

This is used by Campbell Scientific for test purposes and writes a byte to the
memory of the SDM-SIO4.

The address and bytes to write must be in base 10, decimal integer. The address
range is 0-65535 and the byte is from 0-255.