Chief Manufacturing FSR Series User Manual

Page 5

Advertising
background image

Installation Instructions

Model: FSR Series

5

collapsed anchors (20). Tighten until secure (See

Figure 4).

Figure 4: Installation to Drywall

INSTALL DISPLAY TO MOUNT

NOTE: Proper interface must be attached to display. See

instructions that come with interface assembly.

1. Open latching flag by rotating flag clockwise on plate

(10) (See Figure 5).

Figure 5: Open Latching Flag

2. Lift and maneuver display such that all buttons fit into

button openings on plate (10). Lower display firmly

into place. Ensure each button has fully seated in its

button opening (See Figure 6).

NOTE: Mounting buttons are shown in the 100mm x

100mm pattern. Plate (10) will also accomodate
a 75mm x 75mm pattern.

Figure 6: Install Display to Plate

3. Close latching flag by rotating flag counterclockwise

on plate (10) (See Figure 7).

NOTE: An optional padlock may be used to secure

latching flag.

Figure 7: Close Latching Flag

4. Connect cables to display as required.

REMOVE DISPLAY FROM MOUNT

1. Disconnect all cables from display.

2. Open latching flag by rotating flag clockwise on plate

(10) (See Figure 5).

3. Lift and maneuver display mounting buttons out of

button openings.

(20)
(4 places)

(30)
(4 places)

Anchor Screw

(4 places)

(10)

(10)

Latching
Flag

NOTE: Display not shown for clarity.

Button location for
100mm x 100mm
pattern (4 places)

Button location for
75mm x 75mm

pattern (4 places)

NOTE: Display not shown for clarity.

(10)

Latching
Flag

Advertising