A WARNING

The ability to properly perform maintenance on this equip­

ment requires certain expertise, mechanical skills, tools, and
equipment. If you do not possess these, do not attempt to

perform any maintenance on this equipment other than those
procedures recommended in the User’s Manual. FAILURE

TO FOLLOW THIS WARNING COULD RESULT IN
POSSIBLE DAMAGE TO THIS EQUIPMENT, SERIOUS

PERSONAL INJURY, OR DEATH.

A WARNING

Turn OFF the gas and electrical supplies to the unit before
performing any maintenance or service. Follow the operating

instructions on the label attached to the furnace. Failure to

follow this warning could result in personal injury.

The minimum maintenance that should be performed on this

equipment is as follows:

1. Check and clean or replace air filter each month or as required.

2. Check blower motor and wheel for cleanliness and lubrication

each heating and cooling season. Clean and lubricate as
necessary. (See Step 2.)

3. Check electrical connections for tightness, and controls for

proper operation each heating season. Service as necessary.

4. Check for proper condensate drainage; clean as necessary.

5. Check for blockages of combustion-air and vent pipes.

A CAUTION

As with any mechanical equipment, personal injury could

result from sharp metal edges, etc. Be careful when removing

parts.

Step 1—Air Filter Cleaning and Replacement

The air filter arrangement may vary depending on the application.

A CAUTION

Never operate unit without a filter or with filter access door

removed. Failure to follow this warning could result in a fire

or personal injury.

DOWNFLOW FURNACES ONLY - Each furnace accommo­

dates 2 filters which are installed in the return-air duct. (See Fig.

3.) To clean or replace the filters, proceed as follows:

1. Turn OFF electrical supply to unit.

2. Remove blower access door.

3. Reaching up behind top plate, tilt filters toward center of

return-air plenum, remove filters, and replace or clean as
needed.

4. Furnaces are equipped with permanent, washable filters. Clean

these filters by spraying cold tap water through filter in

opposite direction of airflow.

5. Rinse filters and let dry. Oiling or coating of filters is not

recommended.

6. Reinstall filters with cross-mesh binding facing blower.

7. Replace access door.

8. Turn ON electrical supply to furnace.

UPFLOW FURNACES ONLY — To clean or replace the air

filter, proceed as follows:

1. Turn OFF electrical supply to unit.

INSTALLATION

-POSITION

OF FILTERS

A92117

Fig. 3—Position of Filters in Downflow Furnace

CONTROL
BOX

Fig. 4—Filter Installed for Bottom Inlet

AUX J-BOX

& BLOWER
DOOR SWITCH

Fig. 5—Filter Installed for Side Inlet

2. Remove access doors.

3. Release filter retainer spring from behind flange of furnace

casing. (See Fig. 4 and 5.)

4. Slide filter out.

WA

Advertising