Fig. 7—Cleaning Primary Heat Exchanger Cell

(5.) Repeat procedures (previous) until each furnace cell has

been cleaned.

(6.) Using vacuum cleaner, remove residue from each cell.

(7.) Using vacuum cleaner with soft brush attachment,

clean burner assembly.

Step 4—Reassemble Furnace (After Cleaning Heat Ex­
changers)

1. Reinstall coupling box(es):

c. Apply sealant releasing agent (Pam) to coupling box flange

and cell panel where coupling box flange matches. (See

Fig. 8.)

APPLY RELEASE AGENT TO AREA

INDICATED BY SHADING

COUPLING BOX

(INSIDE VIEW)

Fig. 8—Inside View of Coupling Box

A87318

d. Apply a generous bead (3/16-in. diameter) of G.E. RTV

122, 162, or Dow-Corning RTV 738 sealant (NO substi­

tute is permissible) to flange of coupling box. (See Fig. 8.)

Your distributor/dealer should have G.E. RTV 122, 162, or

Dow-Corning RTV 738 sealants in stock.

e. Being careful not to smear sealant, position coupling box so

that slot in insulation is on left side and install coupling
box.

2. Reinstall inducer assembly.

a. Upflow furnace only —Be sure small round gasket(s) is in

place between blower shelf and inducer housing.

b. Apply sealant releasing agent (Pam) to collector box.

c. Apply 1/8-in. diameter bead of G.E. RTV 122, 162, or

Dow-Corning RTV 738 sealant to back of inducer housing.

Apply sealant around inlet air opening. (The sealant should

be about 1/4 in. from the edge of the inlet air opening.) (See

Fig. 9.)

d. Install inducer assembly on collector box and support

bracket to coupling box.

e. Connect 6-circuit inducer motor connector to inducer

controller. Reconnect 6-circuit connector from pressure

switches to main harness. (See Fig. 18.)

f. Reconnect pressure tubes to pressure switch. (See Fig. 10 or

11

.)

3. Connect small drain tube from top of trap to fitting on bottom

of inducer housing. (See Fig. 10 or 11.)

4. Connect 7/8-in. drain tube to trap and collector box; tighten

hose clamps. (See Fig. 10 or 11.)

Fig. 9—Back of Inducer Assembly Housing

Fig. 10—Upflow Furnace Pressure and Drain

Tubing Diagram

5. Reinstall vent pipe and drain tube,

a. Upflow furnace only;

(1.) Reconnect vent pipe. Be sure clamps are tight.