Single line (gravity feed system) – Sears Riello F10 User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Riello manometers and vacuum gauges do
not require any adaptors, and can be safely
connected to the pump ports. An NPT (metric) adapter
must be used when connecting
other gauge models.
SINGLE LINE (GRAVITY FEED SYSTEM)
A)
The burner is shipped configured for use in single line applications. No changes to
the oil pump are required for use in single line applications.
NOTE; If the pump cover (1) is removed for any reason, be sure the 0-ring (2), is properly
seated in the pump cover (1) before re-attaching the pump cover to the pump housing.
SINGLE LINE SYSTEM - PIPE LENGTHS
H
3/8 ’ OD
1/2 ’ OD
FT
M
FT
M
FT
M
1.5
0.5
33
10
65
20
3.0
1.0
65
20
130
40
5.0
1.5
130
40
260
80
6.5
2.0
195
60
325
100
D6009
NOTE: Do not exceed pipe lengths
indicated in chart.
B)
Connect the pipe connector to the SUPPLY PORT (6) of the pump. Attach the required
piping to this pipe connector. Be sure that the plug in the RETURN PORT (9) is tightened
securely.