I ' 7 – Kodak EKTAGRAPHIC 470 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Tray Advance Unreliably?

Compact cassette slide-advance sig­

nals and program-pause signals con­

forming with spacing, frequency, du­

ration, and level characteristics listed

under "Specifications” on page 17 will

operate the AudioViewer/Projector

dependably. Signals not conforming

to these specifications may result in

undependable operation. For example,

slide-advance signals of the correct

frequency (1000 Hz) but of the wrong

duration (other than 0.07 sec.) may

result in erratic slide-tray advance.

(Tapes made in conformance with

ANSI Standard PH7.4-1975 will oper­

ate this machine dependably.)

Tapes recorded with earlier models

of the EKTAGRAPHIC AudioViewer

or EKTAGRAPHIC AudioViewer/

Projector will operate an

EKTAGRAPHIC AudioViewer/

Projector, Models 220, 270, 470, or

570AF dependably, and vice versa.

OWNER’S

MAINTENANCE

Cleaning the Built-In Tape Deck

If possible, clean the built-in tape

deck after every program. Cleaning

the tape deck takes only a few min­

utes and helps prevent buildup of

oxide from tapes and loss of sound

fidelity.

1. Unplug the power cord!

2. Press the tape stop/eject button to

open the cassette well. Then par­

tially close the cassette well door

to position the heads of the tape

deck for more convenient access

for cleaning.

3. Press and hold in the tape play

button to keep the tape heads

forward.

4. Rub the capstan, tape-guide path,

and metallic heads with a cotton

swab moistened with head-clean­

ing solution or isopropyl alcohol.

Do not touch the heads with any

metallic object. A head-cleaning

cassette (available at radio-supply

stores) can be used occasionally,

but a swab dipped in isopropyl

alcohol is preferred.

i

1%

J

I

i ' 7

-WMi

^,

Head-Cleaning Cassette

Cleaning the Built-In Viewing
Screen

Use a soft, damp cloth to clean the

built-in viewing screen. Do not use

lens-cleaning solutions or tissues con­

taining silicone.

The optics and mirrors inside the

AudioViewer/Projector should be

cleaned only by a qualified techni­

cian, such as those at a Kodak Ser­

vice Center (addresses on back cover).

Partial disassembly of the Audio­

Viewer/Projector is required for this

Adjusting the Position of the Image
on the Built-In Viewing Screen

All KODAK EKTAGRAPHIC Audio-

Viewer/Projectors have been designed

to let the owner maintain, and make

minor adjustments to, the machine as

necessary.

The front mirrors have to be read­

justed when the image on the built-in

screen is not in perfect alignment.

Adjustments are made with the

screws located on the front-projection

door. Be sure the image-magnifying

lever is located in its "up” position,

for normal (unmagnified) viewing

of images; then close the front-

projection door.

Vertical Image Alignment

1. Insert a slide into the gate of the

Audio Viewer/Proj ector.

2. Turn the lower left screw to center

the image vertically. (The front-

projection door may need to be

opened slightly to reveal the

screw.)

Clean the tape deck often to prevent buildup of
oxide on the heads and loss of sound fidelity.

Horizontal Image Alignment

1. Insert a slide into the gate of the

AudioViewer/Projector.

2. Turn the upper right screw on the

front-projection door to center the

image from side-to-side.