STEPS TO INSTALL YOUR WATER HEATER (Continued)

WARNING

If the temperature and pressure relief valve ever needs replacing,
use only a valve specified by local codes, but not less than a

combination temperature and pressure relief valve certified by a
nationally recognized testing laboratory that maintains periodic
inspection of production of listed equipment or materials meeting
the requirements for Relief Valves and Automatic Gas Shutoff

Devices for Hot Water Supply Systems, as specified in the latest
edition of ANSI Z21.22. This valve must be marked with a
maximum set pressure not to exceed the marked maximum

working pressure of the water heater. (The relief valve provided
with this heater meets these.requirements.) Install the

replacement valve into the opening provided and marked for this
purpose on the water heater. Do not place any valve between the

temperature and pressure relief valve and the tank. Orient it or

provide tubing so that any discharge from the valve witli exit only
within 6 in. above (or any distance) below the structural floor and
cannot contact any live electrical part. The discharge opening
must not be blocked or reduced In size under any circumstances.
For maintenance and replacement of the temperature and
pressure relief valve see pages 10 and 11.

FIG. 2

IMPORTANT: TO HELP PREVENT POSSIBLE DAMAGE TO

THE WATER HEATER, WE SUGGEST YOU READ STEP 5

CAREFULLY.

5

DRAIN PIPE FROM TEMPERATURE AND

. PRESSURE RELIEF VALVE.

WARNING

The temperature and pressure relief valve is designed to

automatically open to vent dangerously high temperature or
pressure from the water heater. To vent the temperature or

pressure, the drain pipe must allow a free flow of water to a floor drain

or other suitable drain point (CHECK LOCAL CODES). If it cannot
vent properly, and fast enough, the heater could burst and damage

property, or cause severe personal injury. BE SURE TO FOLLOW ALL
GUIDES BELOW WHEN INSTALLING THIS DRAIN PIPE. (Also read
the safety guides on page 2, and “WARNING” above.)
DO WOT operate the water heater unless the temperature and pres­
sure relief valve is in place, correctly piped and working properly.

CAUTION: Do not apply heat to the fitting when making sweat
connections to the temperature and pressure relief valve. Sweat
an adaptor to the copper line before connecting to the valve. It is
imperative that no heat be applied to the water heater connec­
tions as they are joined to the non-metalic structure of the heater.

If the temperature and pressure relief valve needs

repositioning, removing or replacing, two wrenches must

be used — one to turn the valve and one to hold the union
hex nut. Never use only one wrench.

• Use 3/4" pipe and fittings the same size as the outlet of the

temperature and pressure relief valve. DO NOT USE A

SMALLER SIZE PIPE.

Use material that will withstand hot water (210“F), and will

not distort, deform, melt, collapse, etc. Copper or CPVG
plastic pipe and fittings are best to use, to keep weight
stress on the center hex union at a minimum.

DO NOT install valves or fittings in the drain pipe that will

restrict drain flow.

The end of the drain pipe must not have threads, so a

fitting or cap could be turned onto it by mistake.

Temperature and

Pr^ure Relief

Valve

.Seal Ring

Hex Union

Nut

< Re fief Valve)

. Metal Strap or
Wire Fastened to

Overhead Point

for Support

The addition of

a Union at this

point will help

in the

Fopiacement of

the

Temperature

and Pressure

Reiief Valve

should the need

arise.

-Drain Pipe

No Threads

✓ Permitted

on End of Pipe

I—6" Approximate

C^T%^Distance for

End of Drain

Pipe From Floor

Di^in Valve O’' Drain

The end of the drain pipe must be no more than 6 in.

(maximum air gap) above the floor drain as FIG. 2 shows.

• The drain run must not have any dips, bends or low spots

that will trap water. ALL water must drain from the pipe and

relief valve.

Be sure freezing temperatures will not affect the flow of

water from the drain pipe.

Support the drain pipe in some manner to prevent stress

on the water heater fitting. For example, use metal
strapping or wire to an overhead point as shown in FIG. 2.

Following ALL of the above RULES, install the drain pipe. Use
pipe thread seal compound on male pipe threads and tighten
all

connections.

Solder

all

sweat

connections.

(READ

CAUTION IN STEP 5.) REMEMBER DO NOT RESTRICT THE
DRAIN PIPE IN ANY WAY.

O. DRAIN VALVE (FIG. 2).

The drain valve is factory installed. To face the drain valve
outlet in the opposite direction, toward the drain point, FIRST

LOOSEN THE UNION HEX NUT. DO NOT ATTEMPT TO

TURN THE DRAIN VALVE WITHOUT LOOSENING THE HEX

NUT OR YOU WILL DAMAGE THE WATER HEATER BEYOND
REPAIR. POSITION DRAIN VALVE TO THE OPPOSITE
DIRECTION AND RETIGHTEN HEX NUT.

7

FILL WATER HEATER WITH WATER AND

I CHECK FOR PLUMBING LEAKS.

A. Be sure the water heater drain valve is closed by turning

the handle clockwise (

).

B. Open nearby HOT water faucets to allow air to vent from

the water heater aid pipes.

C. Open the water heater cold water supply shut-off valve you

installed in Step 2.

Advertising