• idle fuel needle setting - With throttle

control lever in slow position, turn idle
fuel adjustment needle

in

(clockwise)

until engine begins to die and then

turn

out

(counterclockwise) until

engine runs rough. Turn needle to a
point midway between those two
positions.

• Recheck idle speed. Readjust if

necessary.

ACCELERATION TEST-
• Move throttle control lever from slow to

fast position. If engine hesitates or

dies, turn idle fuel adjusting needle

out

(counterclockwise) 1/8 turn.

Repeat test and continue to adjust, if

necessary, until engine accelerates
smoothly.

High speed stop is factory adjusted. Do
not adjust - damage may result.