Move Run/Stop switch to the “Run” position.

Press the primer bulb three (3) times, waiting two
(2) seconds between each push.

• Grasp starter handle and pull slowly until you feel

some resistance. Then pull cord rapidly to
overcome compression, prevent kickback and start
the engine. Let rope return to starter slowly.

Note: The Pressure Command™ may be placed in
any position during starting or operation. However, for

cold starts, it is recommended that the Pressure

Command™ be placed in the “high" position.

Note: If the engine fails to start after 3 pulls, prime the
engine three (3) times and pull starter rope again.

■ Once the engine has started, disengage the spray

gun safety latch.

HOW TO STOP YOUR CLEANING SYSTEM

Move the Run/Stop switch to the “Stop” position.

Simply shutting off the engine wilt not release

pressure in the system. Squeeze trigger on the

spray gun to relieve pressure in the hose.

Note: A small amount of water will squirt out when

you release the pressure.

Rotate the Dial-A-Cleaner™ selector knob to the
OFF position to prevent chemical leakage.

SIPHONING

DO NOT siphon standing water for your water supply.
Contaminated, brackish or dirty water can damage the

pump. Connect only to household water supply.

TIPS

Never use the garden hose inlet to siphon
detergent or wax.

If you hold the spray nozzle too far away from the
object being cleaned, washing will not be as
effective.

• Always store the cleaning system wiUi №e DiaF

A'Cleaner™ selector knob to the OFF position.