SAFETY / INSTALLATION
4.
Never run pump dry.
To do so can damage internal
parts, overheat the pump (which can cause bums to peo
ple handling or servicing the pump), and
will void the
warranty!
5.
IX>
NOT attempt to oil the pump motor. A special oil has
been put into the motor housing at the factory; use of any
other oU will void the warranty and could damage the
pump.
6. This pump is recommended for use in permanent instal
lations only. This pump has not been invenstigated for use
in swirnining pool areas.
7.
Know the pump application, limitations, and potential
hazards. Not for use with salt water or brine.
AWARNING I
pq
¡jj explosive atmospheres.
Pump
water
oialy
with
this
pump.
Failure
to
follow
this
warning
can
result
in
personal
injury
and/or
property damage.
8. Release all pressure within the system before servicing
any component.
9. Drain water from the system before servicing.
10. Secure the discharge line before starting the pump. An un
secured discharge line will whip, possible causing per
sonal injury and/or property damage.
11. Periodically inspect pump and system components. Perform
routine maintenance as required (See MAINTENANCE).
12. Provide a means of pressure relief for pumps whose dis
charge line can be shut-off or obstructed.
13. Personal Safety:
a. Wear safety glasses at all times when working with
pumps,
b. Keep work area clean, uncluttered and properly
lighted - replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work area.
d. Make workshop child-proof - with padlocks, master
switches, and by removing starter keys.
14. This equipment is only for use on 115 volt (single phase)
and is equipped with an approved 3<onductor cord and
3-prong, grounding-type plug.
A WARNING -j-Q reduce the risk of electric shock,
pull
plug
before
servicing.
This
pump
has
not
been
investigated
for
use
in
swimming
pool
areas.
This
pump
is
supplied
with
a
groimding
conductor
and
grounding-type
attachment
plug.
Be
certain
that
it
is
connected
only
to
a
properly
grounded
ground
ing-type receptacle.
Where
a
2-prong
wall
receptacle
is
encountered,
it
must
be
replaced
with
a
properly
groxmded
3-prong
receptacle
installed
in
accordance
with
the
National
Electrical Code and local codes and ordinances.
15. Protect electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking the cord. Replace or re
pair damaged or worn cords immediately.
16. Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
A
warning
]
Rjsk
of
electric
shock.
If
your
basement
has water or moisture on the floor, do not walk on wet
area
until
all
power
has
been
turned
off.
If
shut-off
box is in basement, call the electric company to shut
off service to the house, or call yotir local fire depart
ment
for
instructions.
Remove
pump
and
repair
or
replace.
Failure
to
foUow
this
warning
can
result
in
fatal electrical shock.
ADDITIONAL INSTALLATION
MATERIALS (Purchase Separately)
Sump Pump Hose Kit, SEARS Stock No. 27909, containing
24' (7.3M) of 1-1/4" flexible plastic pipe, 1-1/4" plastic
adapter and stainless steel clamp. We recommend a Check
Valve, SEARS Stock No. 2789 or 2792.
THE SUMP
Locate sump at lowest place in basement or drained area.
Floor drains or drain tiles can also be tiled into sump.
Minimum sump size is 12" (305mm) in diameter by 24"
(6l0mm) deep for model 390.305001 and 10" (254irun) in
diameter by 20” deep (508mm) for models 390.304790 and
390.305790.
Periodically
inspect
pump,
system
com
ponents, and sump for debris and foreign objects. Keep
sump free from all refuse. Perform routine maintenance as
required. Use a sump cover to exclude refuse from sump.
Consult local code for cover specifications.
Grounded Outlet--^ ^
Sump Cover
Basement Floor
X
Figure I
Pump
Minimum
Minimum
Model
Diameter (D)
Depth (H)
390.305001
12" (305mm)
24" (610mm)
390.304790
10" (254mm)
20" (508mm)
390.305790