Service instructions, Addison electric stove – Vermont Casting ACSB User Manual

Page 6

Advertising
background image

6

Addison Electric Stove

10004324

Firebox Removal

Glass Information

WARNING: Disconnect power before
attempting any maintenance or cleaning
to reduce the risk of fire, electrical shock
or personal injury

1. Unplug the electrical supply to the unit.

2. Let the stove cool if it has been operating.

3. Move the stove away from wall to gain access

to the rear of the unit.

4. Locate the firebox mounting brackets on the side of

the firebox. Remove the screws securing the firebox
to the mounting brackets. (Fig. 3)

5. Remove firebox by sliding it rearward out of the

casing.

6. Gently place firebox on its back on the floor.

7. To reinstall firebox, follow the above procedure in

reverse.

1. Under no circumstances should this product be

operated with missing or broken glass.

2. Do not strike or slam the glass.

3. Do not use abrasive cleaners to clean the glass.

4. This product uses tempered glass. Replacement

glass (with gasket) is available from the manufac-
turer and replacement should be carried out by a
qualified service person.

Replacing Light Bulbs

This stove uses two clear 120 Volt, 60 Watt, E-12
socket base light bulbs (small base, chandelier candle
type). The 60 Watt bulbs are located under the log set/
ember bed. For convenience, if one of the bulbs burns
out, it may be a good idea to replace both of the light
bulbs.

1. Turn off power to the unit by unplugging the power

cord.

2. Let stove cool if it has been operating.

3. Remove firebox from casing. (See Firebox removal)

4. Remove the two screws securing the ember bed and

log set in position. One screw is located on either
side of the ember bed near the front.

5. Examine the bulbs to determine which bulb(s) need

to be replaced.

6. While holding the socket, unscrew defective bulb(s).

7. Install the new light bulb(s) by screwing in while

holding the socket.

8. Reinstall ember bed and log set.

9. Reinstall firebox.

WARNING: Do not exceed 60 watts per
bulb for lights beneath the ember bed.
Use of higher rated bulbs may result in a
fire, causing property damage or per-
sonal injury.

Maintenance of Motors

The motors used on the fan and the flame generator
assembly are prelubricated for extended bearing life
and require no further lubrication. However, periodic
cleaning/vacuuming of the fan/heater unit is recom-
mended.

WARNING: Make sure that the power is
turned off before proceeding.

Service Instructions

Mounting
Brackets
(2 per side)

HS106

Fig. 3 Side view of the stove showing the firebox mounting
brackets.

Advertising