Provison for ventilation

✓

The appliance should be installed into a room or space with an air supply in accor-
dance with BS 5440-2: 2000.

✓

For rooms with a volume of less than 5 m

3

- permanent ventilation of 100 cm

2

free

area will be required.

✓

For rooms with a volume of between 5 m

3

and 10 m

3

a permanent ventilation of

50 cm

2

free area will be required unless the room has a door which opens directly to

the outside air in which case no permanent ventilation is required.

✓

For rooms with a volume greater than 10 m

3

- no permanent ventilation is required.

NB. Regardless of room size, all rooms containing the appliance must have
direct access to the outside air via an openable window or equivalent.

✓

Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation require-
ments.

✓

The above requirements allow also for use of a gas oven and grill but if there are
other gas burning appliances in the same room, consult a qualified engineer.