Trouble shooting chart – MTD 24642S User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TROUBLE SHOOTING CHART

SYMPTOM

POSSIBLE CAUSE (S)

SOLUTION

Engine fails to start

A.

Check fuel tank for gas.

B.

Spark plug lead wire

disconnected.

C.

Faulty spark plug.

A.

Fill tank if empty.

B.

Connect lead wire.

C.

Spark should jump gap between

control electrode and side electrode.

If spark does not jump, replace the

spark plug.

2. Hard starting or loss of

power

A.

Spark plug wire loose.

B.

Dirty air cleaner.

A.

Connect and tighten spark plug wire.

B.

Clean air cleaner as described in

engine manual.

3. Engine overheats

A.

Carburetor not adjusted

properly.

B.

Air flow restricted.

C.

Engine oil level low.

A.

Adjust carburetor. See engine manual.

B.

Remove blower housing and clean as

described in the engine manual.

C.

Fill crankcase with the proper oil.

4. Will not split logs

A.

Reservoir oil level low.

B.

Pump setting incorrect.

A.

Check and fill oil reservoir tank as

instructed in Operation Section.

B.

Adjust pump setting to 3,000 p.s.i.*

5. Leaking cylinder

A.

Broken seals.

B.

Scored cylinder.

A.

Replace seals.*

B.

Replace cylinder.*

NOTE: For repairs beyond minor adjustments, please contact your local service dealer.
^Should be performed by an authorized service dealer only.

15

Advertising
This manual is related to the following products: