Digital-logic ag – Compaq MICROSPACE MSEBX900 User Manual

Page 17

Advertising
background image

DIGITAL-LOGIC AG

MSEBX800/900 Detailed Manual V1.0

17

Operating Temperature

Specification:

MIL-810-501

MIL-810-502

Extended temperature range:
SM800PCX (500MHz)


-40°C to +70°C

Security

e1

Not planned

UL

Not planned

ETS 301

Not planned

CE/SEV

Yes

Safety

AR385-16

If all signals are externally filtered and assembled into an enclosed metallic case!

EMI / EMC Tests

Specification

EMC emission EN61000-6-2:2001
Conducted disturbance

EN55022 Class B

Radiated disturbance

EN55022 Class B

EMC immunity EN61000-6-2

Electrostatic discharge (ESD)

EN61000-4-2
Voltage = 4kV contact / 8kV air, Criteria A

Radiated RF-Field

EN61000-4-3
Level = 10V/m, Criteria A

Electrical fast transients (Burst)

EN61000-4-4
Grade 2: DC-Power lines = 1000V (5/50ns)
Grade 2: AC-Power lines = 2000V (5/50ns)
Grade 2: Signal lines

= 500V (5/50ns)

Criteria B

Surge

EN61000-4-5
Grade 2: DC-Power lines = 1kV, (1.2/50us)
Grade 2: AC-Power lines = 2kV, (1.2/50us)
Criteria B

Conducted disturbances

EN61000-4-6
Voltage = 10V coupled by case, Criteria A

All information is subject to change without notice.