2300 electronic control operation, Initial start up, Standard and economy modes – Cal Spas LTR20051000 User Manual

Page 19

Advertising
background image

Operating Your Spa

2300 Electronic Control Operation

Figure 5. 2300 Electronic Control Panel

Initial Start up

When first powered up, the system will perform a self-diagnostic check, then it will automatically heat to and
maintain 100˚F until you change the set temperature as described in the “Temperature Adjustment” section
below.

Temperature Adjustment (Range 80°F to 104°F)

The 2300 electronic control panel (Figure 5) displays the actual water temperature in Fahrenheit.
To display the temperature that the spa is set to:
• Press either the UP or DOWN button. The temperature setting will flash.
• While the display is flashing, each time you press either the UP or DOWN button, the set temperature will

change up or down one degree.

Standard and Economy Modes

Your new spa is equipped with a heating feature that gives you complete control of the heating system. When
the spa is powered up, it will automatically start in standard heating mode. This is displayed by STANDARD on
the left side of the control panel. In this mode, the heating system will automatically activate whenever the
water temperature drops more than one degree below the set temperature. In the economy heating mode, the
heating system will only activate during filtration times. (Filtration times are set by using the “Setting Filtration
Cycles” instructions on page 17
.)

2005 Spa Owner's Manual

Page 15

8/1/2005