ENGINE AIR CLEANER

Clean and re-oil the foam pre-cleaner every three

months or ever 25 hours of operation, whichever

occurs first. Service the foam pre-cleaner more fre­
quently if you operate the generator in extremely dusty
or dirty conditions (Figure 12):

• Turn KNOB counterclockwise to loosen.

• Remove COVER, FOAM PRE-CLEANER and PAPER FIL­

TER.

• Remove foam pre-cleaner from cover

• Wash foam pre-cleaner in liquid detergent and water.

• Wrap foam pre-cleaner in a cloth and squeeze dry.

• Saturate foam pre-cleaner in engine oil. Squeeze to

remove excess oil and to distribute oil.

• Install foam pre-cleaner into cover, followed by paper filter.

Tabs at edges of paper filter must lock into slots on cover.

Once

each

year

or

every

100

operating

hours

(whichever comes first), replace the paper filter. The
new replacement filter must be a flame retardent type.

Figure 12—Engine Air Cleaner

1"====*=*^ PAPER

FILTER

FOAM

PRE­

CLEANER

COVER

ENGINE SPARK PLUG

Clean engine spark plug and set gap to 0.030 inch
(0.76mm) every 100 hours of operation (Figure 14).

■Clean by scraping or wire brushing and washing with

commercial solvent. DO NOT BLAST CLEAN SPARK
PLUG.

CAUTION: Sparking can occur if wire terminal does
not fit firmly over spark plug terminal end. If neces­
sary, reform wire terminal to obtain a tight fit.

Figure 14 — Engine Spark Plug

hours of operation or once each year, whichever
occurs first.

Figure 15 — Fuel Filter

CLEAN AIR INTAKE SCREEN

Clean all foreign material from the air intake screen
(Figure 13) at lease once every 100 hours of operation.
Clean more often if necessary.

Inspect the area around the generator exhaust muffler

periodically and remove all grass, leaves, dirt, etc. from

this area.

Figure 13 — Cleaning Air Intake Screen

SPARK ARRESTOR MUFFLER

If the generator is not equipped with a spark arrestor

exhaust muffler and is to be used on any forest cov­
ered, brush covered or grass covered unimproved
land, you may have to install a spark arrestor. The
spark arrestor must be maintained in effective working
order by the vehicle owner/operator.

For assistance in ordering, installing and maintaining

spark arrestor exhaust mufflers, contact your nearest
authorized service facility.

Exhaust

mufflers

supplied

by

Generac

are

spark

arrestor types. Generac exhaust mufflers for IM gener­
ators do not have a spark arrestor screen, but are of

the more efficient “toriod” or “swirl" type. To remove
carbon and combustion deposits from such mufflers,

remove the PLUG from muffler and run engine for

about 15 minutes. Shut engine down, let the muffler
cool and install the plug.