Appendices ~ appendix f: serial commands, Return values – ClearOne AP800 User Manual
Page 55

51
Appendices
~ Appendix F: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
<OUTPUTMIX>
OUTPUTMIX=hex word. The selected input will be routed to
the outputs indicated.
OUTPUTMIX=null. Mix Command to return the current
setting for the input.
<OUTPUTMIX> Note:
When entering the hex value of the <OUTPUTMIX>, it is not
necessary to add the leading zeros, only zeros that follow the
value, as in examples 1 & 2, below.
Example 1
The following command routes Pregate Mic Input 1 audio to
Output 1. This command applies only to the box the serial cable
connects to, since a device is not specified.
G-Link Z-B
US
G-Link Y
-B
U
S
G-Link X-B
US
Sub B
US 2
Sub B
US 1
Output D
Output C
Output B
Output A
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
MTRX 18 1
Bit
Hex=1
Example 1: Outputmix Matrix
Example 2
The following command routes Mic Input 1 Post Gate audio to
Output A, B, and C, and to the G-Link X-bus.
G-Link Z-B
US
G-Link Y
-B
U
S
G-Link X-B
US
Sub B
US 2
Sub B
US 1
Output D
Output C
Output B
Output A
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
MTRX 1 4700
Example 2: Outputmix Matrix
Return Values
The command will return the updated matrix condition for the
selected input in the same format as the command was issued.
Bit
Hex=4700