EXTENSION CORDS

1.

Grounded

appliances require a three wire extension cord.

Double Insulated

appliances can use either a two or three wire extension cord.

2.

As the distance from the supply outlet increases, you must use a heavier gauge
extension cord. Using extension cords with inadequately sized wire causes a
serious drop in voltage, resulting in loss of power and possible tool damage.
(See Figure C.)

3.

The smaller the gauge number of the wire, the greater the capacity of the cord. For
example, a 14 gauge cord can carry a higher current than a 16 gauge cord.
(See Figure C.)

4.

When using more than one extension cord to make up the total length, make sure
each cord contains at least the minimum wire size required.

(See Figure C.)

5.

If you are using one extension cord for more than one appliance, add the nameplate
amperes and use the sum to determine the required minimum cord size.
(See Figure C.)

6.

Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified electrician
before using it.

7.

Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 VOLT)

NAMEPLATE

AMPERES

(At Full Load)

EXTENSION CORD LENGTH

25

Feet

50

Feet

75

Feet

100

Feet

150

Feet

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

* Based on limiting the line voltage drop

to five volts at 150% of the rated amperes.

FIGURE C