FIREPLACE and VENTING SPECIFICATIONS

VENT SECTIONS and OFFSETTING ELBOWS

NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 1

1/2

” LESS THAN ITS TOTAL

LENGTH, EXCEPT FOR THE LAST SECTION INSTALLED.

12"

305mm

24"

610mm

36"

914mm

48"

1219mm

7TDVP8

7TDVP12

7TDVP24

7TDVP36

7TDVP48

7TDVP1218

7TDVP3564

8"

203mm

7"

178mm

35"

889mm

64"

1626mm

10

"

254mm

18

"

457mm

TRIBUTE 36CDVXR REAR VENT GAS FIREPLACE

Tribute 36CDVXR

FEATURES:

• 36" Tribute Direct Vent Gas Appliance
• 14,700 to 21,000 BTU/hr. input
• 18"Gas Inlet Flex Line with Shut-Off Valve
• 2 Piece Log Set Fastened
• Embossed Refractory
• Attached 17' Low Voltage Wire Connected to Valve for
Remote Operation Hook-Up
• Includes Electrical Recepticall

Accessories:

FK12 - Fan and Cord (160cfm) (for RN/RP only)
RC1/RC2 - Universal Remote Controls
IMTFK - IMT Thermostat w/ Face Plate

Dedicated Tribute DV Venting Components:

7TCRVT -

Rear Vent Kit includes: Rigid Flue Assembly, Hot

Touch Termination which telescopes between 7" and

13" and Firestop

7TCDV45KT - Flex Pipe Assembly extends 13" to 32", Firestop

& Termination

7TCDV90 -

90 Degree Elbow

Bulk Flex Vent Kits*

7FDVCK -

Bulk Flex Connector Kit(Includes: 10 4" Clamps

and 10 7" Clamps to secure the flex vent to the fireplace

and termination)

7FDVSPK -

Bulk Flex Spacer Kit (Includes: 10 Spring Spacers)

VSK7 -

Vertical Vent Kit

BURNER SYSTEM:

• Capacity

– Natural:

21,000 BTU/HR Max.

14,700 BTU/HR Min.

– Propane:

21,000 BTU/HR Max.

15,750 BTU/HR Min.

• Fuel - Natural or Propane Gas

Clearance to Combustibles:

Top of Unit to Ceiling

36” (914 mm)

Front of Unit of Combustibles

36” (914 mm)

Appliance

Top

0” (0 mm)

Bottom

0” (0 mm)

Side

0” (0 mm)

Back

0” (0 mm)

Venting

Concentric sections of DV Vent

Top, bottom & sides

1” (25 mm)

NOTE: Hood must be permanently installed with

three (3) sheet metal screws supplied in Fireplace.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

9

1/4

"

7

1/4

"

9

1/4

"

90°

7"

13"

9

1/4

"

90°

13"

7

1/ 4

"

13"

17"

OFFSET

235mm

235mm

178mm

184mm

330mm

330mm

335mm

330mm

184mm

OFFSET w/2-90°

Back to Back

FIREPLACE FACTS

The Fireplace Facts Information Sheets are

for quick reference only and are subject

to change without notice. Actual fi replace

instructions must abide by specifi cations

provided with each product.

CONTEMPORARY TERMINATIONS

7TDV45

7TDVRT90

11"

7

3/8

"

45°

45°

7

3/8

"

OFFSET w/2-45°

Back to Back

45°

7

3/8

"

188mm

188mm

188mm

FP890

FP889

ELBOWS

7"

7TDVSKV

7"

7TDVSKS

32"

6

1/2

"

813mm

127mm

19"

16"

482mm

406mm

165

mm

5"

7TDRVT

7TRVT

13.25”

10.5”

9.75”

11.5”

REV. 09/07

FLUE SYSTEM

FLUE SYSTEM

36CDVR Certified to - ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

PRODUCT LISTING

7” Coaxial Direct Vent System
SPECIFICATIONS:

• 7” O.D.

• 4” I.D.

MINIMUM CLEARANCE TO COMBUSTIBLE

MATERIAL

a) Rear Wall Vent Applications 2” top, 1” Sides & Bottom

b) Vertical Side Wall Applications 1” to All Sides

c) Vertical thru the Roof Applications 1” to All Sides

MINIMUM COMBUSTIBLE WALL/FLOOR OPENINGS

a) 9 3/8” W x 9 3/8” H for Rear Wall Vent Applications

b) 9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Applications

MAXIMUM INSTALLATION LENGTHS

a) Rear Wall Vent Applications

• 20” to 32” outside wall, and of vent outlet thru wall to be 24 1/4”

up from floor, use 7TCDV45FT

• 7” to 13” straight out

• Corner Installation: 7TCDV45KT must be used. Vent outlet and

thru wall must be 29 1/2” from floor

b) Vertical Side Wall Applications

20ʼ (6 m) Horizontal Vent Length with 7.5ʼ (2.29 m) vertical rise

*Refer to manual for alternative venting distance

VERTICAL THRU THE ROOF APPLICATIONS

• 8ʼ (2.4 m) Minimum Vertical Rise

• 40ʼ (12 m) Maximum Vertical Rise

• 2 sets of 45° Elbows can be used in Vertical rise with 8ʼ

maximum distance between elbows

• Two 90° elbows maximum for 10ʼ (3 m)

• Horizontal can be installed in Vertical Applications

*Maximum angular variation for Vertical Sidewall/Vertical Application

in system is total of 270°

*Refer to installation manual for all venting restrictions with elbow use

TERMINATION CLEARANCES MINIMUM

a) Horizontal

12” (305 mm) above Grade Level

18” (458 mm) to Ventilated Soffit

12” (305 mm) to Unventilated Soffit

12” (305 mm) under veranda, porch, deck or balcony

b) Vertical

24” (610 mm) Above a Roof Surface and any other

obstruction within a horizontal distance of 18” (458 mm)

*Refer to installation manual for more termination restrictions and

clearance information

This appliance may be installed in an aftermarket permanently located,

manufactured home or mobile home, where not prohibited by local

codes.This appliance is only for use with the type of

gas indicated on the rating plate. This appliance is

not convertible for use with other gases, unless

a certified kit is used. The CDVXR has been

approved for mobile home installations.

VERTICAL SIDEWALL INSTALLATION

Rnd.

Vertical Side Wall Installations

Framing

Detail

"

9 3/8”

(240mm)

9 3/8”

(240mm)

Fireplace Hearth

Venting Opening for Combustible Wall

Opening for Noncombustible Wall

V0584-100