Product Specifications

Table 1-1 lists the functional specifications for the DWZZH Hub.

Table 1–1 DWZZH Hub Functional Specifications

Feature

Specification

SCSI ID
SCSI Addresses

The small UltraSCSI HUB does not use a SCSI ID.
The large UltraSCSI HUB uses SCSI ID 7 for
arbitration.

Overload Protection
DTERMPOWER
STERMPOWER

TERMPOWER is not supplied to the external ports
of the UltraSCSI HUB. Internal TERMPOWER is
protected via a resetable fuse. TERMPOWER must
be supplied from the remote connection to enable
each HUB port.

Shielding
Enclosure &
Connectors

Shielded for ESD, EMI, and safety requirements

Power-Up Reset

Automatically clears

Initiator detection circuit

Target detection circuit

BSY glitch filter

SCSI Bus Reset

Automatically clears

Initiator detection circuit

Target detection circuit

BSY glitch filter

Single-Ended SCSI Bus
Length
Ultra (20 megatransfers per
second or 40 MB/s)

20 meters (66 feet) per segment

Differential SCSI Bus Length

25 meters (82 feet) per segment

Data Timing

The relationship between the data and the control
signals is brought to SCSI compatibility before
transmission to the other SCSI bus.

Design

High reliability SMT