Installation, Wiring required, Actual ta-f terminal locations – Aiphone TA-1F User Manual
Page 2: Installation for wall mounting, Equipment available for use with your ta-f, A phone system, Aand ta—f, A stations
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
* Door station TC—D
type
A can be installed with adaptor DF—U
type
A to master stations TA—3F
type
A , TA—6F
TYPE A, or TA—12F TYPE A. (Up to two door stations may be connected to up to 5 masters.)
* Phone system may be connected to existing paging and background music system using adaptor PG—U
TYPE A
* Talkback paging available through existing paging system using adaptor PA-B.
INSTALLATION
Do not attempt to install your intercom system until you have read and thoroughly understood the installation
procedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.
Lay out your system in advance. Determine the exact location of each station. We recommend a full comple
ment of wire be installed, even though you may not initially be installing the maximum number of stations available
to your system. This way, should you decide to add a station later, you can avoid running additional cables to
existing stations. Do not connect wires to terminals D1 or D2 unless appropriate equipment is used. Phone system
will not operate if these wires are connected in parallel through system.
WIRING REQUIRED
TA—IF - 5 Conductors maximum
TA—6F - 12 Conductors maximum
TA—3F - 9 Conductors maximum
TA—12F - 18 Conductors maximum
Refer to the chart below and select the proper wire gauge to meet your requirements.
AWG WIRE SIZE
24 AWG
22 AWG
20 AWG
18 AWG
DISTANCE
1300'
2100'
3300'
5300'
DIAMETER OF WIRE
0.5 mm
0.65 mm
0.8 mm
1.0 mm
DISTANCE
400 m
650 m
1000 m
1450 m
Begin your installation with station #1. A space is provided at the left of the diagram to write in your color
code. Note the position of the C terminal at each station. Be sure you wire each station correctly.
After installing your second station we recommend that the power supply be connected to the + and - terminal
lines at a convenient location and that a test be made for calling and talking between each station. As each addi
tional station is. installed re-test between each station. Unplug power supply while making wiring connections.
ACTUAL TA-F TERMINAL LOCATIONS
TA-1F
type
a
TA-3F
type
A
TA-6F
type
A
P 0
D2
0
di
<2
30
c0
20
-0
,0
+ 0
6 0
P0
50
D20
40
D10
30
C0
20
_0
,0
+0
INSTALLATION FOR WALL MOUNTING
1) Attach the mounting bracket to wall or
single gang plaster ring.
2) Attach handset cradle included , as shown in
illustration.
TA-12F
type
A
60 120P0
50 110D20
40 1Q0D10
30 90 c0
20 80 _0
10 70 +0
(T) — @ ; for connecting relative stations
( + ) — © : for power supply
© : for receiving call and talking
@ — @ ; for connecting door station
0 : for paging
EQUIPMENT AVAILABLE FOR USE WITH YOUR TA-F
type
A PHONE SYSTEM
TA-IF TYPE A ; 1 call master station with
paging button.
^ TA-3F TYPE A ; 3 call master station with
paging button and door station capability.
TA-6F TYPE A : 6 call master station with
paging button and door station capability.
■
TA—12F TYPE A ; 12 call master station
with paging button and door station
capability.
TC D Type A: Surface or semi-flush mount
door station with push button for calling
connected master.
P
DF—U TYPE A: Adaptor for door station.
Required between door station TC—D
type
A
and TA—F
type
A stations.