Installation, Wiring required, Actual ta-f terminal locations – Aiphone TA-1F User Manual

Page 2: Installation for wall mounting, Equipment available for use with your ta-f, A phone system, Aand ta—f, A stations

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

* Door station TC—D

type

A can be installed with adaptor DF—U

type

A to master stations TA—3F

type

A , TA—6F

TYPE A, or TA—12F TYPE A. (Up to two door stations may be connected to up to 5 masters.)

* Phone system may be connected to existing paging and background music system using adaptor PG—U

TYPE A

* Talkback paging available through existing paging system using adaptor PA-B.

INSTALLATION

Do not attempt to install your intercom system until you have read and thoroughly understood the installation

procedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.

Lay out your system in advance. Determine the exact location of each station. We recommend a full comple

ment of wire be installed, even though you may not initially be installing the maximum number of stations available

to your system. This way, should you decide to add a station later, you can avoid running additional cables to

existing stations. Do not connect wires to terminals D1 or D2 unless appropriate equipment is used. Phone system

will not operate if these wires are connected in parallel through system.

WIRING REQUIRED

TA—IF - 5 Conductors maximum

TA—6F - 12 Conductors maximum

TA—3F - 9 Conductors maximum

TA—12F - 18 Conductors maximum

Refer to the chart below and select the proper wire gauge to meet your requirements.

AWG WIRE SIZE

24 AWG

22 AWG

20 AWG

18 AWG

DISTANCE

1300'

2100'

3300'

5300'

DIAMETER OF WIRE

0.5 mm

0.65 mm

0.8 mm

1.0 mm

DISTANCE

400 m

650 m

1000 m

1450 m

Begin your installation with station #1. A space is provided at the left of the diagram to write in your color

code. Note the position of the C terminal at each station. Be sure you wire each station correctly.

After installing your second station we recommend that the power supply be connected to the + and - terminal

lines at a convenient location and that a test be made for calling and talking between each station. As each addi­

tional station is. installed re-test between each station. Unplug power supply while making wiring connections.

ACTUAL TA-F TERMINAL LOCATIONS

TA-1F

type

a

TA-3F

type

A

TA-6F

type

A

P 0

D2

0

di

<2

30

c0

20

-0

,0

+ 0

6 0

P0

50

D20

40

D10

30

C0

20

_0

,0

+0

INSTALLATION FOR WALL MOUNTING

1) Attach the mounting bracket to wall or

single gang plaster ring.

2) Attach handset cradle included , as shown in

illustration.

TA-12F

type

A

60 120P0
50 110D20

40 1Q0D10

30 90 c0
20 80 _0

10 70 +0

(T) — @ ; for connecting relative stations

( + ) — © : for power supply

© : for receiving call and talking

@ — @ ; for connecting door station

0 : for paging

EQUIPMENT AVAILABLE FOR USE WITH YOUR TA-F

type

A PHONE SYSTEM

TA-IF TYPE A ; 1 call master station with

paging button.

^ TA-3F TYPE A ; 3 call master station with

paging button and door station capability.

TA-6F TYPE A : 6 call master station with

paging button and door station capability.

TA—12F TYPE A ; 12 call master station

with paging button and door station

capability.

TC D Type A: Surface or semi-flush mount

door station with push button for calling

connected master.

P

DF—U TYPE A: Adaptor for door station.

Required between door station TC—D

type

A

and TA—F

type

A stations.