V. start-up and adjustment, Vi. maintenance – Bryant 905D User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

V. START-UP AND ADJUSTMENT

1. Open saddle valve to permit water to flpw into

humidifier pan. Make sure all connections are

tight and there are no water leaks. Check drain

plug; if necessary, tighten plug by turning handle

clockwise.

2. Allow humidifier pan to fill. As water approaches

top of overflow tube, make sure float-valve

closes, stopping water flow 1/2 to 3/4 inch below

top of overflow.

3. Plug humidifier motor cord into service cord.

4. Start heating unit. When heating unit blower

starts, look through sight glass to see if disc

assembly is rotating. If humidistat is used, circuit

must be made through it.

5. Stop heating unit. When blower stops, look

through sight glass to be sure disc assembly stops.

6. If installation includes cooling, start cooling unit.

When blower motor of heating unit starts, look

through sight glass to be sure disc assembly is

NOT rotating.

7. Leave these instructions with homeowner.

VI. MAINTENANCE

Each spring

I

the humidifier pan should be removed

and cleaned/.

1. Disconnect humidifier service cord.

2. Turn off water supply to humidifier.

3. Hold bucket under humidifier pan; remove drain

plug and empty water from humidifier into

bucket (approximately 2 gallons).

4. Disconnect water supply line from humidifier.

5. Turn latches 1/4 turn and remove humidifier.

6. Remove disc assembly by lifting end of shaft op­

posite motor and pulling away from motor at

same time. Replace disc assembly when, space

between discs is less than 1/4 inch, and solids

cannot be easily removed. (When discs are

plugged, airflow is not necessarily reduced—only

when the space between the discs is clogged

enough to restrict airflow.)

7. Clean humidifier pan before reassembling.

8. Reverse procedure outlined in Steps 1-6 for

reassembling. However, if installation includes

cooling, do not turn on water supply to

humidifier (Step 2) until start of heating season.

NOTE: During the heating season, humidifier pan

should be drained and flushed once a month.

.-.T.T-_. ...

*.

Figure 3—Installing Humidifier

-3-

Advertising