Altec Lansing 9441A User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Operating and Service Instructions for the Altec Lansing 9441A Power Amplifier

9

SERVICE

INFORM­

ATION

WARNING;

No

user

serviceable

parts

inside.

Extremely

hazardous

voltages and currents may be en­

countered within the chassis. The

servicing

information

contained

within

this

document

is

only

for

use

by

Altec

iMusing

authorized

warranty

repair

stations

and

qualiped

service

personnel.

To

avoid electric shock DO NOT per­

form any servicing other than that

contained

in

the

Operating

Instr­

uctions unless you are qualified to
do so. Otherwise, refer all servi­

cing to qualified senice personnel.

NOTICE:

Modifications

to

Altec

Lansing

products

are

not

recom­

mended.

Such

modifications

shall

be

at

the

sole

expense

of

the

pcrson(s)

or

company

responsible,

and

any

damage

resulting

there­

from shall not be covered under

warranty or otherwise.

9.2 Equipment Needocl

To precisely adjust the

trimpots, you must have tlie fol­
lowing equipment:

1 — Digital DC volt meter

2 —

4 Cl

load rated at 200

watts

1 — Small non-conducting
flat-blade screwdriver or

set of p l a s t i c T V
alignment tools

Miscellaireous handtools

(to remove the top cover)

NOTE;

If you need to verify the

amplifier's

performance

against

the

rated specipcations,

you must

be able to maintain the ac line
voltage constant at 120 V ac (or

240 V ac if wired according to

Figure

2).

Therefore,

we

recom­

mend a suitably rated variac (50
ampere rating at 120 V ac).

9.2

Adjusting

VR02

and

VR102,

the

BIAS

Trimpot

To adjust VR02 and VR102 for
the proper bias, follow the pro­
cedures below:

1.

Turn power off and dis­

connect the unit from its
power source. Make sure
the unit is in the Dual

mode with 4 D loads con­
nected to each channel.

2.

Remove the ten screws se­
curing the top cover.
Refer to Figure 1 for the
.screw locations.

3.

Channel 1:

Locate the

junction of Ql2’s emitter

and R37. Connect the pos­
itive side of the digital DC
volt meter to the junction
of QI2’s emitter and R37.
Then locate the junction
of Ql4’s emitter and R38.
Connect the negative side
of the digital DC volt
meter to the junction of
Ql4’s emitter and R38.
Connect the unit to its

power source and turn the
power on. Adjust VR02 so
that the digital DC volt
meter reads 7 milli volts
DC (± .2 mVdc). Turn
power off and disconnect
the unit from its power
source.
Note; Adjust Bias im­
mediately

after

turning

power on.

4.

Channel 2:

Locate the

junction of Qll2’s emitter

and R137. Connect the
positive side of the digital
DC volt meter to the

junction of Q112’s emitter

and R137. Tlien locate

the junction of Qll4’s

e m i t t e r

and

R138.

Connect the negative side
of the digital DC volt
meter to the junction of
Qll4’s emitter and R138.
Connect the unit to its

power source and turn the

0

.

9.7

power on. Adjust VR102
so that the digiUiI DC volt

meter reads 7 milli volts

DC

.2 mVdc). furn

power off and disc'.'iinect
the unit from its pow'er
source.
Note:

Adjust r.ias im­

mediately after Lii ruing
power on.

Re-install the lop cover
with the ten screws pre­
viously removed.

Oi'ilex'ing

Replacement

Parts
To

order

replacvinent

parts,

look

up

the

<r.lering

number from the componen, parts
listing and call (405) 32-5-531L,
FAX (405) 324-8981, or wrih-:

Altec I.ansing
Replacement Parts Sales
P.O. Box 26105
Oldahoma City, OK 73120-0105

9.8

Factory Service

If factory ser\ ice is

required, ship the unit ;;i its

original packing prepaid tv

Altec Lansing Customer
Service/Repair

10500 W. Reno

Oklalioma City, OK 73128

Enclose a note describing the pro­

blem in as much detail as possible.

Include any additional helpful in­
formation such as test conditions,
where used, how used, etc,

9.9

Technical

Assisi

anee

For applications assistance

or other technical information,
contact the Technical Services
Manager. You can call (405) 324-
5311, FAX (405) 324-8981, or
write:

Altec Lansing
Technical Services Manager
P.O. Box 26105

Oklalioma City, OK 73126-0105

ALTEC LANSING'^ CORPORATION • a Mark IV Company

11