FIGURE 14

MAINTENANCE

®G

WARNING I

Always stop engine and disconnect
spark plug wire before performing any

maintenance or adjustments.

ENGINE OIL

Change oil first two (2) hours of operation and

check oil level every five (5) operating hours or each
time equipment is used.

Change oil every twenty-five (25) operating hours

or sooner if equipment is operated in exiremely

dusty or dirty conditions.

Refer to engine manual for quantity and type of oil.

LOG SPLITTER RESERVOIR OIL

Check oil in log splitter reservoir before every use.

See figure 15.

1. Block up front of log splitter so beam is evel.

2.

Remove check pipe plug in rear of bearri. See

figure 15. If oil starts to come out of check pipe

plug hole, oil level is correct. IF IT DO El 5 NOT,

add oil to breather tube (see figure 8) until oil
starts out.

NOTE

Use hydraulic sealant tape or p pe

sealant on pipe plug threads.

3.

Replace check pipe plug. Remove block from'

under front of beam.

FIGURE 15

Change oil in the reservoir every (100) hours of

operation.

1. Remove the hose clamp at inlet hose (bottom

hose on rear of beam). See figure 16.

NOTE

Be prepared to catch oil in a suitable

container.

2. Pull off inlet hose from strainer tube assembly and

catch oil in a suitable container. See figure 16,

3.

With an adjustable wrench remove the strainer

tube assembly. See figure 16.

NOTE

The strainer tube assembly is 53" long.

4.

Drain oil, clean strainer tube and reassemble

using a hydraulic pipe sealant on the threads.

5.

Remove the breather plug from breather tube.

See figure 8. Pour approximately 2-1 /2 gallons of

Dexron transmission fluid ONLY into breather

tube.