Introduction, Features – Connect Tech CANPRO CTIM-00043 User Manual

Page 5

Advertising
background image

CANpro/104 User Manual


CTIM-00043 (0.01) 1/15/2010

www.connecttech.com

5

800-426-8979 | 519-836-1291

Introduction

CANpro/104 combines the power of two independent NXP SJA1000 CAN controllers with the compact size
and rugged stability of PC/104. CANpro/104 is ideal for industrial control applications exposed to harsh
conditions or environments. CANpro/104 Opto models feature 2.5 kV of data and power isolation.

Features

Two independent, industry standard NXP SJA1000 CAN controllers

PC/104 compliant

16MHz input clock (24MHz build option available)

Fail-safe power-up/power-down using on-board impendence transceivers to maximize nodes on the bus
and ensure glitch-free operation.

Supports up to 1.0 Mbps operation and over 120 nodes on the bus

2000 V(AC) 50/60 Hz sine wave, 2500 V (peak) signal and power isolation for each port from the host
system (on CANpro/104 Opto models only)

Jumper configurable:

address range and interrupt sharing

output slew rate limiting for lower radiated emissions

-120 Ohm CAN bus termination

Decoded address range is configurable for BasicCAN and PeliCAN modes

Ten pin right angled header standard as an I/O connector (DB-9 option available)

Operating temperature range of -40°C to +85°C

+5V power output on some models

RoHS compliant