Line termination -11, Figure 4: rs-485/422 partial schematic -11 – Connect Tech JB2 User Manual

Page 31

Advertising
background image

Chapter 4: Appendices – RS-485/422 Interface

4-11

Titan/cPCI User’s Manual, ver. 0.00

Line Termination

You can use jumper blocks JC, JD, JE and JF to terminate and
bias TxD ±, RxD ±, RTS ±, and CTS ± on the individual RS-
485/422 ports through jumper selectable 150

Ω fixed resistors.


Please refer to Figure 4 for a partial schematic of the RS-485/422
circuit for the Titan/cPCI and to Figure 1 for the locations of JC,
JD, JE and JF.

Figure 4: RS-485/422 partial schematic

TxD

TxD +

RxD -

TxD -

RxD +

Titan/cPCI

RS-485/422 Line Bias/Termination

RxD

RTS

RTS +

CTS -

RTS -

CTS +

CTS

PCI 954

UART

150

Ω

1.8K

Ω

1.8K

Ω

+5 V

150

Ω

1.8K

Ω

1.8K

Ω

+5 V

150

Ω

JC5, JD5, JE5, JF5

150

Ω

JC6, JD6, JE6, JF6

JC3, JD3, JE3, JF3

JC4, JD4, JE4, JF4

JC1, JD1, JE1, JF1

JC2, JD2, JE2, JF2

10K

Ω

DTR

JA0, JA1, JA2, JA3

Note: Line bias/termination is jumper selectable

Advertising
This manual is related to the following products: