Daewoo DWP-28W2ZLF User Manual

Page 67

Advertising
background image

Appendix Service manual WP-795

- 40 -

On normal run mode, I501 microcontroller pin 63 (power) is set to high

So, I810 controlled rectifier is not conducting

- Q809 is conducting. So, Q808 is not conducting and Q807 is conducting
- So, Q807 collector is connected to the ground and I810 controlled rectifier gate pin is set

to low (no conducting)

So, current from 11V DC voltage (from T801 SMPS transformer pin 13) does not flow through Q811
and Q810 transistors but flows through I806 IC error amplifier

- Q809 is conducting. So, Q810 is not conducting and no current flows from Q810 collector

to the ground


Therefore, the power circuit diagram is the following one:

2-9-2-1-2 power supply circuit diagram during TV set normal run