Appendix Service manual WP-795

- 40 -

On normal run mode, I501 microcontroller pin 63 (power) is set to high

•

So, I810 controlled rectifier is not conducting

- Q809 is conducting. So, Q808 is not conducting and Q807 is conducting
- So, Q807 collector is connected to the ground and I810 controlled rectifier gate pin is set

to low (no conducting)

•

So, current from 11V DC voltage (from T801 SMPS transformer pin 13) does not flow through Q811
and Q810 transistors but flows through I806 IC error amplifier

- Q809 is conducting. So, Q810 is not conducting and no current flows from Q810 collector

to the ground


Therefore, the power circuit diagram is the following one:

2-9-2-1-2 power supply circuit diagram during TV set normal run