Electrical connection
Local and national electrical regulations must be observed.
All instructions given by the Electricity Board must be followed
carefully when connecting the oven to the mains supply,
This is a job for a qualified and approved electrician. The appli-
ance is rated for 240 volts single phase and must be permanently 
connected.
The cooker must be installed in such a way that it can be easily 
disconnected from the mains supply before servicing, e.g., by an 
adjacent cooker oontrol unit.
Sufficient cable should be iett to enable the appliance to be re
moved from the housing unit whilst still connected to the mains 
supply.
WARNING - THIS APPLIANCE MUST BE EARTHED!
Voltage and current
Please ensure that the voltage and current indicated on the rating 
plate agrees with the voltage of your electricity supply, 220-240 
volts i.e., 220-240 V a.c.
1, Open the cover of the terminal box sideways as illustrated in
fig. G,
'
-
2. Pass cable through the grommet in the lower back panel and
the cable clamp.
3. Connect the wires to the terminals in accordance with the dia
gram. Ensure that links are correctly positioned between ter
minals (5 or 6 way terminal block). The length of the earth con
ductor must be adequate to ensure that in case of the cable 
clamp breaking the earth wire is subject to mechanic strain 
only after the live wires.