For the kitchen furniture installer – AEG VITRAMIC 725K User Manual

Page 12

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

For the kitchen furniture installer

Safety instructions

Please note that veneers and plastic coatings
on the unit housings must be treated with heat-
resistant adhesive (100°C). Uniess the plastic
coatings and adhesives are heat-resistant, the
coating may deform or come loose.

The use of solid wood wali upstands behind
the hob is allowable so long as the minimum

distances indicated in the hob diagrams are
complied with.
Surface discoiourations of the wali upstand are

not due to temperature effects of the appiiance.
For temperature reasons, cut out any upper
panels of base units below the hob.

Owing to the

risk of fire,

ensure that no flam­

mable or thermally deformable objects are

placed directly below the hob.

Do not install a drawer below build-in hobs.

An intermediate panel must be fitted, that can

only be detached with tools,

at least 50 mm

beneath the hob

for safety (contact protec­

tion) reasons.

There should be no cross-strips below the

worktop cutout. They should be sawn back at

least as far as the worktop cutout size.

The minimum distances of hob cutouts to the

rear are indicated in the installation diagrams

(figure 5).

During installation beside an upright kitchen
housing, a

safety distance of at least 50' mm

must be ensured. The side surface of the

upright kitchen housing should be lined with

heat-resistant material.

For reasons of good working practice,

the

distance laterally to upright kitchen units

should be

at least 300 mm.

The distance between the hob and vapour

extractor hood must be of the extent indi­
cated in the installation instructions of the

vapour extractor hood.

Hob Cutout

Use the template supplied for your “Soft Line”
ceramic hob.

Figure 5

Hobs with a width of 77 cm should be fitted

over only two 60 cm base units (rather than

three) to avoid the loss of the third drawer

space. Please make sure that the cutout is

accurately made. You should therefore use

only a good, straight fretsaw blade or else

a routing cutter.

The cutting surfaces must be sealed.

The range of the clamping brackets extends

from 30 mm to 40 mm. With thicker worktops

recesses should be provided in the worktop
at suitable points.

The clamping brackets are fastened according
to

figure 6/1,2.

Hob Instaliation

1

. Take the mean according to

figure 8.

2.

Attach fixing bracket to

figure 9.

3. Cut off top half fixing brackets

(figure 10)

with a knife.

4.

Insert hob according to

(figure 7)

and place

it horizontally, level in the worktop.

5.

The

two

clamps firmly fitted on both sides

will grip under the fixing brackets

(figure 11)

and retain the hob. For removing it proceed

in reverse order.

Important

Under no circumstances should drawers be

fitted in either of the base units straddled by
the hob.

12