INSTALL DIVERTER

When finished tiling the wall, remove PLASTER GUARD (1).

Remove two screws that secure the DIVERTER LID (2) and
remove Lid. Inspect the inside surface of diverter port.
Diverter port must be free of any dirt. Clean if necessary.

Install DIVERTER

(3)

with SCREWS

(4)

removed with

DIVERTER LID

(2).

Operate DIVERTER

(3).

DIVERTER

(3)

should slide in

and out smoothly.

DIVERTER

PORT

INSTALL VALVE TRIM

Figure 1. Push CAP

(1)

over VALVE CARTRIDGE

(2)

until

seated against stop. Push CAP

(3)

over DIVERTER

(4)

until

seated against stop.

Figure 2. Push ESCUTCHEON HOLDER

(5)

onto CAP(1J

and attach with SCREWS [S). Mount ESCUTCHEON
SUPPORT

(7J

to ESCUTCHEON HOLDER

(5)

with

SCREWS (8).

Figure 3. Align PINS (10) on back side of ESCUTCHEON (11)

with the FOUR HOLES (12) in ESCUTCHEON SUPPORT

(7)

and press ESCUTCHEON (11) flush against finished wall.

Figure 1.

Figure 2.

M968836