Dayton 3VG79 User Manual

Dayton portable forced air heaters, 3vg79

Advertising
background image

Operating Instructions & Parts Manual

3VG79

Dayton Portable Forced
Air Heaters

Description

Dayton Model 3VG79 is a 200,000 Btu/Hr heater. This heater uses Kerosene or #1
fuel oil for combustion and electricity to run the motor. It is primarily intended
for indoor or outdoor temporary heating of buildings under construction,
alteration, or repair. It may be used in agricultural, industrial, and commercial
environments.

®

Form 5S4068

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Unpacking

1. Remove all packing items applied to

heater for shipment.

2. Remove all items from carton.

3. Check items for shipping damage. If

heater is damaged, promptly inform
dealer where you bought heater.

Figure 1 - Model 3VG79

ARL LOGO

G 004

®

Amperage

Model

Electrical Input

(during normal run)

3VG79

120 Volt/60 Hertz

4.5

ELECTRICAL SPECIFICATIONS

GENERAL SPECIFICATIONS

Output

Fuel Tank Capacity

Fuel Consumption

Model

Rating Btu

Fuel

(U.S. Gallons)

(U.S. Gallons/Hr.)

Motor RPM

3VG79

200,000

Kerosene or No. 1 fuel oil

13.5

1.4

3450

Fuel Pump

Heater Weight

Heater Weight

Spark Plug Gap

Model

Pressure (PSI)

(Pounds - with fuel)

(Pounds - without fuel)

(Inches)

3VG79

6

77

66

.110

Version B - For Reduction

G016.J

®

© 1997 W.W. Grainger, Inc.
Printed in U.S.A.
03430
0895/206/VCPVP

Advertising