Altec Lansing 1270 User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

OUTPUT

■0"

3a. Independent Operation of

L and R Channels

NOT CONNECTED

0" "0-

NOT CONNECTED

STEREO (INDEPENDENT CHANNEL)
OPERATION

1. After Installation and hookup of connec­

tions as in Figure 3A, check that the

BRIDGE/NORMAL switch is positioned

at NORMAL, and that the LEFT and

RIGHT CHANNEL volume controls are

turned fully counterclockwise. (°°).

2. Set input signal level to the 1270 at a

nominal value of 0.775V.

3. Turn on ac line POWER switch and note

illumination of POWER indicator.

4.

Turn LEFT and RIGHT CHANNEL vol­

ume controls clockwise until desired

output power is obtained. If either LEFT
or RIGHT peak/error indicator illumi­

nates, reduce output level with channel

volume control or reduce input level to

1270.

3. Turn on ac line POWER switch and note

illumination of POWER indicator.

4. Turn LEFT OHANNEL volume control

clockwise until desired output power is
obtained. Be sure to leave RIGHT CHAN­
NEL volume control fully counterclock­
wise. If LEFT peak/error indicator illu­
minates, reduce output level with LEFT
CHANNEL volume control, or reduce
input level to the 1270.

CAUTION

Bridged operaton provides a true bal­

anced output. Do not connect either
side of the loudspeaker line to audio
common or to any other “ground”
connection.

3b. Bridge Operation of

L and R Channels

Figure 3. Output Connections

BRIDGE (MONO) OPERATION

1. After installation and hookup of connec­

tions as in Figure 3B, check that the

BRIDGE/NORMAL switch is positioned

at BRIDGE, and that the LEFT and

RIGHT CHANNEL volume controls are

turned fully counterclockwise {“).

2. Set input signal level to the left (L) INPUT

of the 1270 at a nominal value of 0.775V.
(The right (R) INPUT is left unconnected.)

—3—