Operating heater, Continued, Shutting off heater – Desa VRL24NR User Manual

Page 20: Shutting off burners only (pilot stays lit)

Advertising
background image

110021-01G

For more information, visit www.desatech.com

For more information, visit www.desatech.com

20

Figure 34 - Control Knobs, Selector Switch and Ignitor Button
Locations for Hand-Held Remote Operation

Figure 32 - Pilot (Propane/LP)

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 33 - Pilot (Natural)

Ignitor
Electrode

Pilot Burner

Thermocouple

Shutting Off Heater

1.

Turn control knob clockwise

to the OFF position.

2.

Turn rear burner control knob clockwise

to the

OFF position.

3a. Set selector switch in the OFF position.

3b.

If Using Optional Hand-Held Remote:

Set selector switch

in the OFF position to prevent draining battery.

1.

Follow steps 1 through 6 under Lighting Instructions, page 20.

2.

Depress control knob and light pilot with match.

3.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow steps
9 through 11, Lighting Instructions
, page 19 and column 1.

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the

OFF position when you are away from home for long
periods of time. Heater will come on automatically
with selector switch in the ON position.

OPERATING HEATER

Continued

O

F

F

PI

LOT O

N

AU

T

O

OFF

ON

Figure 31 - Control Knobs and Ignitor Button Locations (Shown
as Supplied, No Remote Control Operation)

Rear Burner
Control Knob

Selector
Switch

Ignitor Button

Control Knob

OPERATING HEATER (REMOTE-READY MODELS)

Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Optional Remote Operation

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

OPTIONAL HAND-HELD

REMOTE OPERATION

NOTICE: You must light the pilot before using the
hand-held remote control unit. See

Lighting Instruc-

tions, page 19.

1.

After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide the selector switch
to the REMOTE position (see Figure 34).

Note:

The burner

may light if hand-held remote was on when selector switch
was last turned off. You can now turn the burner on and off
with the hand-held remote control unit.

IMPORTANT:

Do not leave the selector switch in the RE-

MOTE or ON position when the pilot is not lit. This will
drain the battery.

O

F

F

PI

LOT O

N

AU

T

O

OFF

ON

Rear Burner
Control Knob

Selector
Switch

Ignitor Button

Control Knob

11. To light the front/rear burners, push in and turn rear burner

control knob counterclockwise

to the ON position.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one
of the following:

1.

Turn control knob clockwise

to the PILOT position.

2.

Turn rear burner control knob clockwise

to the

OFF position.

3.

Use remote control manual OFF button.

4.

Set selector switch in the OFF position.

Note:

All remote control accessories must be purchased sepa-

rately (see Accessories, pages 38 and 39). Follow instructions
included with the remote control.

Advertising
This manual is related to the following products: