Model: MIL-4711H

5

A s s i g n i n g a n I P A dd r e s s

Every device on a TCP/IP network is identified by two addresses:

• The address is a 6-byte address assigned to the 4711H by the manufacturer.

• The IP address is a 4-byte address assigned by the system admin. Set this.

The MIL-4711H stores its IP address in its NVRAM (default: 0.0.0.0).

Caution:

When the address is 0.0.0.0, the 4711H uses RARP or BOOTP to acquire an address.

The following are ways to assign an IP address to the hub:

• Make a telnet connection via port 2002, or connect serially and set the IP

address manually.

• Use a RARP server to set the address each time the MIL-4711H powers up.

• Use BOOTP to set the address each time the MIL-4711H powers up. This is the

preferred method in larger networks as BOOTP can work through routers.

Note:

Neither telnet nor RARP work if the server is connected through a router on a different
subnet from the MIL-4711H. To assign an IP address, put the MIL-4711H on the same
subnet as the host, set-up an ARP entry with an IP address that is valid for that subnet,
telnet to the unit, and assign an appropriate IP address.

S e t t i n g t h e I P A dd r e s s w i t h Te l n e t

The following only works if the MIL-4711H is on the same subnet as the host from
which you want to telnet. In this example, you are to add a MIL-4711H called

alpha

with an IP address

192.185.2.3

and an Ethernet address of

0040c800012B

.

To set the IP Address using Telnet:

1. Use a text editor to open the /etc/hosts file.

2. Add the following line and save the file:

192.185.2.3 alpha

3. Use this to set the static ARP entry for a host on the same subnet as the 4711H:

arp -s alpha 00:40:c8:00:01:2B

4. Set the rear panel DIP switches D2 up and D1 down and power cycle the unit.

5. Make a telnet connection to maintenance port 2002:

telnet alpha 2002, or connect an ANSI compatible terminal to the RS-232 port

6. Type [!] to enter the monitor menu.