TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Battery in remote control

is either missing or has low

power

2. Remote control is not pointed

toward fireplace

3. Manual ignition bypass

switch not in OFF position

4. No power available to

fireplace

5. Ignitor electrode not con-

nected to ignitor cable

6. Broken ignitor cable

7. Ignitor electrode broken

8. Ignitor electrode positioned

wrong

1. No power available to

fireplace

2. Manual ignition bypass

switch not in OFF position

3. Wall switch wire harness is

disconnected

1. Burner orifice clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too

low

2. Burner orifice clogged

OBSERVED PROBLEM

When buttons on remote control

are pressed, there is no response

from fireplace

When wall switch button is

pressed, there is no response

from fireplace

Burner does not light after ODS/

pilot is lit

Delayed ignition burner

REMEDY

1. Replace battery in remote

control

2. Point remote control toward

lower front panel of fireplace

when operating

3. Place manual ignition bypass

switch in OFF position

4. Make sure power cord is

plugged into electrical outlet

and outlet has power

5. Reconnect ignitor cable

6. Replace ignitor cable

7. Replace electrode

8. Replace ODS pilot

1. Make sure power cord is

plugged into an electrical

outlet and outlet has power

2. Place manual ignition bypass

switch in OFF position

3. Check continuity of wall

switch wire harness. Make

sure plug on wall switch wire

harness is fully inserted into

socket on circuit board in fire-

place. Replace if necessary

1. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

2. Contact local gas company

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

Advertising