Checking gas connections, Continued – Desa CFN2800BTB User Manual

Page 16

Advertising
background image

16

101809

ON

POSITION

OFF

POSITION

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and

water to gas joints. Bubbles forming show a leak.

5. Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1. Close manual shutoff valve (see Figure 14).
2. Pressurize supply piping system by either using compressed air or opening main

gas valve located on or near gas meter.

3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply

mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open manual shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure

15). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 17 through 19). Check all other

internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appliance, page 19).
8. Replace front panel.

Manual
Shutoff
Valve

Figure 14 - Manual Shutoff Valve

Gas Meter

Figure 15 - Checking Gas Joints

Manual
Shutoff
Valve

Open

Closed

CHECKING

GAS

CONNECTIONS

Continued

Thermostat Gas Valve

Advertising
This manual is related to the following products: