Cleaning and maintenance, Specifications – Desa SL30NT User Manual

Page 15

Advertising
background image

104463-01E

For more information, visit www.desatech.com

For more information, visit www.desatech.com

15

15

LOGS

• If you remove logs for cleaning, refer to Installing Gas Log

Heater into Stove, page 10, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All
slotted burner flame holes should be open with yellow flame present.
All round burner flame holes should be open with a small blue flame
present. Some burner flame holes may become blocked by debris or
rust, with no flame present. If so, turn off heater and let cool. Remove
blockage. Blocked burner flame holes will create soot.

Figure 26 - Pilot Inlet Air Hole

Burner
Tube

Pilot Assembly

Pilot Air Inlet Hole

Ports/Slots

CLEANING AND
MAINTENANCE

Continued

CLEANING AND MAINTENANCE

Logs

Main Burner

SPECIFICATIONS

4.

Check the injector holder located at the end of the burner tube
again. Remove any large particles of dust, dirt, lint, or pet hair
with a soft cloth or vacuum cleaner nozzle.

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 26). With the unit off, lightly blow
air through the air inlet hole. You may blow through a drinking straw
if compressed air is not available.

SPECIFICATIONS

Btu (Variable)

16,000/30,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

28 lbs.

* For input adjustment