Dpc ii plus ac power cord part numbers – Dukane DPC II Plus 9001:2000 User Manual

Page 31

Advertising
background image

21

Dukane Manual Part No. 403–566–01

Section 3 – Unpacking and Installation

Ꮨ

Ꮨ

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

+

–

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

Earth Ground

#14 Gauge
Wire

110 VAC or
220 VAC

Grounding Lug

Grounding Lug

Ultrasound

Input

Automation
Control

Status
Output
P/N 200–1302

Coaxial Cable

RG62B/U

#14 Gauge Wire

Automation

Equipment

P/N 200–1203

P/N 200–479

Ẅ

Ẅ

Ẉ

ẇ

Ẇ

ẅ

ẅ

Ꮨ

Ꮨ

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

+

–

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

J901 T

O

THR

USTER

J902 B

ASE/

ABOR

T

Jumper Block
Part No. 200–1293

Pins 3 & 9
Connected

1

5

3

6

9

Earth Ground

#14 Gauge
Wire

Flexible + Coaxial Cable
20kHz Part No. 200–624
40kHz Part No. 200–759
(Included with probe)

Grounding Lug

110 VAC or
220 VAC

14–Pin AMP to

HD–15 Adapter

Part No. 200–1248

Ẅ

Ẉ

ẉ

ẇ

Ẇ

ẅ

The 3–prong AC Line cords supplied are
matched to the DPC II Plus power rating and
the continent of specified use.
The part numbers are —
200–1109

North America 110V

200–1110

North America 220V

200–1111

Continental Europe

Figure 3-4 DPC II Plus and EZ Welder Hand Probe Cable Connections

Figure 3-5 DPC II Plus and EZ Welder Automated Probe Cable Connections

Table 3—

II

DPC II Plus AC Power Cord Part Numbers

Step 4.

Optional – Attach the status output
cable from the user–supplied
automation equipment to the System
Output DB-25 connector. Not all
automation systems will have this cable.

Step 5.

Attach the power cord to the DPC II
Plus and plug the other end into an
approved AC outlet.

Advertising