Owner’s manual, Installation – Desa VMH26TNB User Manual

Page 15

Advertising
background image

15

107029

OWNER’S MANUAL

INSTALLATION

Continued

Figure 24 - Removing Branch Support From Fireplace

CONNECTING EQUIPMENT
SHUTOFF VALVE TO
HEATER CONTROL

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not

provided)

1.

Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.

2.

Remove screws that attach branch sup-
port to fireplace (see Figure 24). Care-
fully lift up branch support and remove
from fireplace (see Figure 24).

3.

Route flexible gas line, included, from
fireplace control to equipment shutoff
valve through side or rear access holes
in outer casing.

NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 24).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.

Flexible Gas Line from
Fireplace Gas Regulator
Provided With Fireplace

Figure 25 - Attaching Flexible Gas Line to Equipment
Shutoff Valve

Equipment
Shutoff Valve

To Gas
Supply

4.

Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line/equipment shutoff
valve (see Figure 25).

5.

Check all gas connections for leaks. See
Checking Gas Connections, page 16.

6.

Replace branch support back into fire-
place. Feed flexible gas line into fire-
place base area while replacing branch
support. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach branch support to fireplace with
screws removed in step 2.

Branch
Support

Screen

Shoulder
Screw

Flexible
Gas Line

Continued

To Fireplace
Gas Regulator

CAUTION: Avoid damage to

regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.

Advertising